damaged,  it  should  be  replaced  by  a  cable  of  special  assembly  to  be  furnished  by  the 
manufacturer  or  post-sale  service.  Such  replacement  should  be  performed  by  qualified 
technical service only. 
The machine should be places in such a way as to allow a minimum space between the back 
and the wall to allow an easy access and without risks to the cable jack. 
Safeguard the base of the jack. 
It  is  advisable  to  install  a  power  switch  and  the  appropriate  electrical  safety  devices  in 
accordance with local and/or national regulations in each case. 
 
 
 

 
 
START-UP 
Previous Checkup  

a)  Is the machine leveled?  
b)  Voltage and frequency are the same as those on the nameplate? 
c)  Are the discharges connected and operating?  
** If air condensed:  Is the air circulation and its temperature appropriate?  

** Is water pressure appropriate?  

 

 
 

 

NOTE:

 In case input water pressure is higher that 0,6 MPa (6 Bar) install a pressure reducer. 

THE FAUCETCONNECTION PRESSURE SHOULD NEVER BE REDUCED. 

 
START-UP 

Once  the  installation  instructions  are  followed  (ventilation,  site  conditions,  temperatures, 

water quality, etc.), proceed as follows: 

1)  Connect to drinking water network.

 

Open the water inlet. Verify the existence of leakages.  

2)  Open the door and remove the protection elements that are inserted on the curtain. 
3)  Connect the machine to the electrical network.  
4)  Verify that there are no vibrations or frictions on the elements. 
5)  Verify that the curtain moves freely. 
6)  The machine  has  a  timer  governing  startup,  allowing  for  water  to  be  recharged  for  the 

production cycle 

7)  Verify  that  the  nozzles  send  the  water  to  the  evaporator  on  the  right  direction  (even 

spread).  

8)  Check the cubes after two cycles; they should be uniform in shape. If they do not come 

out correctly, or the unit does not make ice, contact an authorized service technician. 

9)  The unit produces ice until the bin is full, using a stop sensor. When the ice is removed 

from the bin, the unit will once again produce ice. 

     ROOM 

 

WATER

 

 

MAXIMUM 

 

     43ºC  (109.40ºF)              35ºC (95ºF) 

 

MINIMUM 

 

     5ºC (41ºF) 

             5ºC (41ºF) 

 

MINIMUM 

 

0.1 MPa (1 Bar) 

MAXIMUM 

 

0.6 MPa (6 Bar) 

Voltage  and  tension  are  indicated  in  the  nameplate  and  on  the  technical 
specifications  of  this  manual.  Variation  on  voltage  above  the  10%  stated  on  the 
nameplate could result on damages or prevent the machine start-up.

 

 

Summary of Contents for NG R290

Page 1: ...formed by qualified and certified professional personnel only Any use by the ice maker not intended to produce ice using drinking water is considered inappropriate It is extremely dangerous to modify or intend to modify this machine and shall make any type warranty void This device is not intended for use by persons including children whose physical sensory or mental capacities are limited or who ...

Page 2: ...icinity of the appliance Do not operate on off switches or plug unplug power cables in the vicinity of the appliance Do not use a direct flame Ventilate the area around the appliance immediately by opening doors and windows Notify an authorized service technician In order to assure the proper operation and efficiency of this equipment it is of paramount importance to follow the recommendations of ...

Page 3: ...s the previous one Nameplate On the back of the machine Check that in interior of the machine the installation kit is complete and comprises Ice scraper gas pipe 22 mm 0 86 inches discharge hose two filters and manual INSTALLATION EMPLACEMENT GUIDELINES An incorrect installation of the equipment may cause damages to individuals animals or other materials being the manufacturer not responsible for ...

Page 4: ...rough the grids and this air has to go to the environment and not accumulate This is particularly important with the air ejected from the back of the machines you must leave a space to the wall of a minimum 10 cm allowing air to flow from behind and with an exit so that there is a renewal of the same avoiding the formation of hot air pockets in this area that could reduce the ice production of the...

Page 5: ...the machine level at 150 mm 5 91 inches minimum It is convenient that the drainage pipe is of 30 mm 1 18 in of interior diameter and with a minimum gradient of 3 cm 1 18 in per meter see figure Electrical Connection Caution The positioning of the device must ensure that the power connection is not damaged or pinched Do not install multiple portable power outlet strips or other portable power suppl...

Page 6: ...tions temperatures water quality etc proceed as follows 1 Connect to drinking water network Open the water inlet Verify the existence of leakages 2 Open the door and remove the protection elements that are inserted on the curtain 3 Connect the machine to the electrical network 4 Verify that there are no vibrations or frictions on the elements 5 Verify that the curtain moves freely 6 The machine ha...

Page 7: ...the faucet 3 Disconnect the water inlet and outlet from the condenser 4 Prepare a solution at the 50 of phosphoric acid and distilled or demineralized water 5 Make the solution circulate through the condenser The solution is more effective if hot between 35ºC 95ºF and 40ºC 104ºF DO NOT USE HYDROCHLORIC ACID Air Condenser 1 Disconnect the machine 2 Disconnect the water inlet or close the faucet 3 C...

Page 8: ...r Leak Control When working on the machine always check the water connections status of the clamps and hoses with the purpose of avoiding leakages and prevent damages or floods WATER QUALITY WARRANTY In areas with water hardness outside the range of 15ºF to 40ºF water filters or descaling systems are required to protect the ice machine The Warranty will cease to exist if the mentioned protective m...

Reviews: