damaged, it should be replaced by a cable of special assembly to be furnished by the
manufacturer or post-sale service. Such replacement should be performed by qualified
technical service only.
The machine should be places in such a way as to allow a minimum space between the back
and the wall to allow an easy access and without risks to the cable jack.
Safeguard the base of the jack.
It is advisable to install a power switch and the appropriate electrical safety devices in
accordance with local and/or national regulations in each case.
START-UP
Previous Checkup
a) Is the machine leveled?
b) Voltage and frequency are the same as those on the nameplate?
c) Are the discharges connected and operating?
** If air condensed: Is the air circulation and its temperature appropriate?
** Is water pressure appropriate?
NOTE:
In case input water pressure is higher that 0,6 MPa (6 Bar) install a pressure reducer.
THE FAUCETCONNECTION PRESSURE SHOULD NEVER BE REDUCED.
START-UP
Once the installation instructions are followed (ventilation, site conditions, temperatures,
water quality, etc.), proceed as follows:
1) Connect to drinking water network.
Open the water inlet. Verify the existence of leakages.
2) Open the door and remove the protection elements that are inserted on the curtain.
3) Connect the machine to the electrical network.
4) Verify that there are no vibrations or frictions on the elements.
5) Verify that the curtain moves freely.
6) The machine has a timer governing startup, allowing for water to be recharged for the
production cycle
7) Verify that the nozzles send the water to the evaporator on the right direction (even
spread).
8) Check the cubes after two cycles; they should be uniform in shape. If they do not come
out correctly, or the unit does not make ice, contact an authorized service technician.
9) The unit produces ice until the bin is full, using a stop sensor. When the ice is removed
from the bin, the unit will once again produce ice.
ROOM
WATER
MAXIMUM
43ºC (109.40ºF) 35ºC (95ºF)
MINIMUM
5ºC (41ºF)
5ºC (41ºF)
MINIMUM
0.1 MPa (1 Bar)
MAXIMUM
0.6 MPa (6 Bar)
Voltage and tension are indicated in the nameplate and on the technical
specifications of this manual. Variation on voltage above the 10% stated on the
nameplate could result on damages or prevent the machine start-up.