Water and Drainage
Water quality has a remarkable influence on the appearance, hardness
and flavor of the ice as well as, on the machines condensated by water,
on the life of the condenser.
Connections to the Water Network
Use a flexible pipe (1.3 m
– 4.27 feet length) with the two filter joints
supplied with the machine. Arrange the necessary appliances
according to regulations or current norms to prevent water return to
the network.
Pressure should be established between 0.1 MPa and 0.6 MPa (1-6
BAR)
If pressures overpass such values, install the necessary corrective devices.
Connection to Drainage
Drainage should be located lower to the machine level, at 150 mm (5.91 inches) minimum. It
is convenient that the drainage pipe is of 30 mm (1.18 in) of interior diameter and with a
minimum gradient of 3 cm (1.18 in) per meter (see figure).
Electrical Connection:
Caution:
•
The positioning of the device must ensure that the power connection is not damaged or
pinched.
•
Do not install multiple portable power outlet strips or other portable power supplies in back
of the device.
The machine is supplied with a 1.5 m (4.92 feet) cable of length. In case the supply cable is
IT IS MANDATORY TO GROUND THE EQUIPMENT
To avoid possible discharges on individuals or damages to the equipment, the
machine should be grounded pursuant local and/or national regulations as the case
may be.
THE MANUFACTURER SHALL BE HELD HARMLESS IN CASE OF DAMAGES
ARISING DUE TO THE LACK OF THE GROUND INSTALLATION.