Air Condenser-filter
1) Disconnect the machine.
2) Take out the front louver. (pull out the lower clips)
3) Vacuum clean, wash or substitute the filter.
4) Dismantle the lateral lid that covers the condenser
5) If it is necessary clean the louvered area with the help of an aspirator with a
brush, non-metallic brush or low-pressure air.
Evaporator / water container
1) Prepare a solution at the 50% of phosphoric acid and distilled water. Do not use
hydrochloric acid. Pour this solution slowly in the top of the evaporator, until it
overflows in the water container. The mixture is more effective with the water
between 35ºC and 40ºC.
2) Leave the solution acting during 10 minutes.
3) Take out the overflow, wait until the water container is empty. Place the
overflow.
4) Close the water inlet.
5) Refill the system until the maximum level of the water container with the same
solution. Connect the machine (the water must be closed) and wait 20 minutes.
6) Open the water, connect the machine.
CAUTION: ** Eliminate the ice manufactured in this first cycle.
NOW THE SANITARY CLEANING STARTS.
6) Connect the machine and once there is no more water entering, remove the
evaporator lid and pour the bleach (one glass) in the same. Wait 20 minutes.
7) Disconnect the machine and connect it again, once the ice has fallen, THROW
it and leave the machine performing the complete cycle.
CAUTION: ** Eliminate the ice manufactured with this procedure.
8) Clean and mount all the components, and check that the louver is clean and
that the ice cubes slide well. Check that in the shield no slat gets blocked.
Review and/or change the water input filters.