20) Everything seems to be working
properly,
but
no
ice
is
manufactured in the evaporator.
A) The pump lost prime.
A) Check the overflow pipe;
ensure the water container
doesn’t leak, the water inlet
valve is in good condition
and prime the pump.
B) Damaged pump.
B) Change.
C) No water enters the container.
C) Check
water
inlet
electrovalve and change if
necessary.
D) The water container is left without
water.
D) Check the overflow pipe and
possible water losses.
E) There’s humidity in the system.
F) Change
the
dehydrator,
generate vacuum and load.
F) Inefficient
refrigeration
system.
(dirty condenser, damaged or badly
regulated
pressure
switch
or
condensation water inlet valve or
lack of coolant).
G) Check
components
and
system.