1.2. Descripción
Main Features of the Machine
18/8 stainless steel housing
Powerful speed reducer (24Kg./m. @ 7 rpm.)
Copper evaporator on precision bored tubing (HB 50)
Durable stainless steel auger with resilient coating
Ice drops out of the bottom of unit
Speed reducer in top part of the unit
Ecological refrigerant R404a
1.3. Principio de funcionamiento
Water enters water trough via a float valve which provides a constant head of water. Through a
hole in the bottom of the trough, water flows into the bottom of the evaporator and floods it to
the same height as in the water trough. Water freezes upon contact with evaporator wall, and is
scraped off as ice by the vertical, rotating auger. Ice is carried upward until it passes through
discharge flap and falls into bin. When bin is full, automatic shut-off sensor (micro-switch on
discharge flap) switches off machine.
IMPORTANT!
If unit is placed on top of a cold room, and/or ice has to fall a long distance from unit, a
MECHANICAL ICE LEVEL SENSOR
should be installed. To prevent ice from compressing in
cold storage, we recommend transferring ice through a plastic tube (80-100 mm diameter)
attached to its lower end the
DISPERSION CONE
which is
PROVIDED WITH THE MACHINE
in all models.
Summary of Contents for GIQ 1100
Page 6: ...ICE QUEEN TECHNICAL SERVICE MANUAL 6 1 4 Wiring diagrams ...
Page 7: ...ICE QUEEN TECHNICAL SERVICE MANUAL 7 ...
Page 8: ...ICE QUEEN TECHNICAL SERVICE MANUAL 8 ...
Page 9: ...ICE QUEEN TECHNICAL SERVICE MANUAL 9 ...
Page 10: ...ICE QUEEN TECHNICAL SERVICE MANUAL 10 ...
Page 11: ...ICE QUEEN TECHNICAL SERVICE MANUAL 11 ...