7
SPIKA NG 130
SPIKA NG 160
SPIKA NG 230
SPIKA NG 360
8.-INSTALLATION OF MODULAR EQUIPMENTS ON TOP OF BINS
Modular ice makers should be installed on top of bins, following the instructions contained in this manual.
The resistance and stability of the container-machine/s assembly should be verified, as well as the fastening elements. Follow bin manufacturer instructions.
•
FACTORY SETTINGS
•
Head pressure regulator: 10 bar.
•
Pressure switch protection: 30 bar.
Start-Up
1.- Previous Checkup
a)
Is the machine leveled?
b)
Voltage and frequency are the same as those on the nameplate?
c)
Are the discharges connected and operating?
d)
Will the ambient temperature and water temperature remain in the following range?
ROOM
WATER
MAXIMUM
109º F / 43º C
95º F / 35ºC
MINIMUM
41º F / 5º C
41º F / 5ºC
e)
Is water pressure appropriate?
MINIMUM
14 psig (1 Bar)
MAXIMUM
85 psig (6 Bar)
NOTE: In case input water pressure is higher than 85 psi (6 bar), install a pressure regulator.
For undercounter machines: