Figure 14: Example of incorrect horizontal alignment (top view)
4.
Repeat the previous steps until the permitted reading value is achieved.
4.4.7 Perform parallel alignment for a vertical correction
Refer to the alignment table in "Permitted indicator values for alignment checks" (see Table of Contents
for location of table) for the proper cold alignment value based on the driver temperature rise and the
pump operating temperature.
Before you start this procedure, make sure that the dial indicators are correctly set up.
A unit is in parallel alignment when the parallel indicator (P) does not vary by more than 0.05 mm |
0.002 in. as measured at four points 90° apart at the operating temperature.
1.
Set the parallel alignment indicator (P) to zero at the top-center position (12 o’clock) of the driver
coupling half (Y).
2.
Rotate the indicator to the bottom-center position (6 o’clock).
3.
Record the indicator reading.
When the read-
ing value is...
Then...
Negative
The pump coupling half (X) is lower than the driver coupling half (Y). Remove
shims of a thickness equal to half of the indicator reading value under each driver
foot.
Positive
The pump coupling half (X) is higher than the driver coupling half (Y). Add shims of
a thickness equal to half of the indicator reading value to each driver foot.
1
Item Description
1.
Shims
Figure 15: Example of incorrect vertical alignment (side view)
4.
Repeat the previous steps until the permitted reading value is achieved.
4.4 Pump-to-driver alignment
3640 i-FRAME API Type BB2 2-Stage / ISO 13709 2nd Ed. API 11th Ed. Installation, Operation, and Maintenance Man-
ual
27