Nameplate field
Explanation
II
Group 2
2
Category 2
G/D
Use when gas and dust are present
T4
Temperature class
The code classification marked on the equipment should be in accordance with the specified area where
the equipment will be installed. If it is not, please contact your ITT/Goulds representative before proceed-
ing.
WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure the pump driver and all other auxiliary components meet the required area classifica-
tion at the site. If they are not compatible, do not operate the equipment and contact an ITT
representative before proceeding.
3.2 Nameplate information
Model 3355 Installation, Operation, and Maintenance Manual
17