Nameplate on the pump casing using metric units
Figure 5: Nameplate on the pump casing using metric units
Nameplate field
Explanation
MODEL
Pump model
SIZE
Size of the pump
FLOW
Rated pump flow, in cubic meters per hour
HEAD
Rated pump head, in meters
RPM
Rated pump speed, in revolutions per minute
HYDRO PRESS
Hydrostatic pressure at 38°C in kilopascals gauge
MAX. DES. WORKING PRESS Maximum working pressure at temperature °C in kilopascals gauge
S/N
Serial number of the pump
CONT./ITEM NO.
Customer contract or item number
IMP. DIA.
Rated impeller diameter, millimeters
MAX. DIA.
Maximum impeller diameter, millimeters
STD. DIM.
Standard ANSI dimensional code
MAT'L
Material of construction
ATEX nameplate
Figure 6: ATEX nameplate
Nameplate field
Explanation
II
Group 2
2
Category 2
G/D
Use when gas and dust are present
T4
Temperature class
WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure the pump driver and all other auxiliary components meet the required area classifica-
tion at the site. If they are not compatible, do not operate the equipment and contact an ITT
representative before proceeding.
3.3 Nameplate information