ATEX IDENTIFICATION
For a pumping unit (pump, seal, coupling, motor and
pump accessories) to be certified for use in an ATEX
classified environment, the proper ATEX identification
must be present.
The ATEX tag would be secured to the pump or the
baseplate on which it is mounted. A typical tag would
look like this:
The CE and the Ex designate the ATEX compliance.
The code directly below these symbols reads as
follows:
II
= Group 2
2
= Category 2
G/D
= Gas and Dust present
T4
= Temperature class, can be T1 to T6
(see Table 1)
Table 1
Code
Max permissible
surface temperature
o
F (
o
C)
Max permissible
liquid temperature
o
F (
o
C)
T1
842 (450)
700 (372)
T2
572 (300)
530 (277)
T3
392 (200)
350 (177)
T4
275 (135)
235 (113)
T5
212 (100)
Option not available
T6
185 (85)
Option not available
The code classification marked on the equipment
should be in accordance with the specified area
where the equipment will be installed. If it is not,
please contact your ITT/Goulds representative before
proceeding.
INTENDED USE
The ATEX conformance is only applicable when the
pump unit is operated within its intended use. All
instructions within this manual must be followed at all
times. Operating, installing or maintaining the pump
unit in any way that is not covered in this manual can
cause serious personal injury or damage to the
equipment. This includes any modification to the
equipment or use of parts not provided by ITT/Goulds.
If there is any question regarding the intended use of
the equipment, please contact an ITT/Goulds
representative before proceeding.
CONDITION MONITORING
For additional safety precautions, and
where noted in this manual, condition
monitoring devices should be used. This
includes, but is not limited to:
♦
Pressure gauges
♦
Flow meters
♦
Level indicators
♦
Motor load readings
♦
Temperature detectors
♦
Bearing monitors
♦
Leak detectors
♦
PumpSmart control system
For assistance in selecting the proper instrumentation
and its use, please contact your ITT/Goulds
representative.
ANSIFAM IOM - 12/03
9
1
Summary of Contents for Goulds Pumps 3196
Page 1: ...Installation Operation and Maintenance Instructions ANSI FAMILY ...
Page 4: ...4 ANSIFAM IOM 12 03 ...
Page 6: ...6 ANSIFAM IOM 12 03 ...
Page 10: ...10 ANSIFAM IOM 12 03 ...
Page 12: ...This Page Intentionally Left Blank 12 ANSIFAM IOM 12 03 ...
Page 28: ...BASEPLATE LEVELING WORKSHEET 28 ANSIFAM IOM 12 03 ...
Page 44: ...44 ANSIFAM IOM 12 03 ...