COUPLE PUMP AND DRIVER
s
!
WARNING
Lock out driver power to prevent accidental
rotation and physical injury.
The coupling used in an ATEX classified
environment must be properly certified.
1.
Install and lubricate coupling per manufacturer’s
instructions.
2.
Install coupling guard (Fig. 26). Refer to Coupling
Guard Installation and Disassembly Section
Appendix II
.
The coupling guard used in an ATEX
classified environment must be
constructed from a non-sparking material.
s
!
WARNING
Never operate a pump without coupling guard
properly installed. Refer to Appendix II for
coupling guard installation instructions.
Personal injury will occur if pump is run without
coupling guard.
36
ANSIFAM IOM - 12/03
Service temperature in an ATEX classified environment is limited by Table 1 in the SAFETY section.
Table 3
Impeller Clearances
Cold Temperature Clearances for Various Service Temperatures, inches (mm)
Service Temperature
3196 and HT3196
LF3196
STX
MTX/LTX
XLTX/X17
STX MTX/LTX
inches
mm
inches
mm
inches
mm
inches
mm
-20 to 150°F (-29 to 66°C)
0.005
0.13
0.008
0.20
0.015
0.38
0.015
0.38
Up to 175°F (79°C)
0.005
0.13
0.008
0.20
0.015
0.38
0.015
0.38
Up to 200°F (93°C)
0.005
0.13
0.008
0.20
0.015
0.38
0.015
0.38
Up to 250°F (121°C)
0.006
0.16
0.009
0.23
0.016
0.41
0.016
0.41
Up to 300°F (149°C)
0.007
0.19
0.010
0.26
0.017
0.44
0.017
0.44
Up to 350°F (177°C)
0.009
0.22
0.012
0.29
0.019
0.47
0.019
0.47
Up to 400°F (204°C)
0.010
0.25
0.013
0.32
0.020
0.50
0.020
0.50
Up to 450°F (232°C)
0.011
0.28
0.014
0.35
0.021
0.53
0.021
0.53
Up to 500°F (260°C)
0.012
0.30
0.015
0.38
0.022
0.56
0.022
0.56
Up to 550°F (288°C)
0.013
0.33
0.016
0.41
0.023
0.59
0.023
0.59
Up to 600°F (316°C)
0.014
0.36
0.017
0.44
0.024
0.62
0.024
0.62
Up to 650°F (343°C)
0.016
0.39
0.019
0.47
0.026
0.65
0.026
0.65
Up to 700°F (371°C)
0.017
0.42
0.020
0.50
0.027
0.68
0.027
0.68
Table 3, cont’d
Impeller Clearances
Cold Temperature Clearances for Various Service Temperatures, inches (mm)
Service Temperature
CV 3196
1
3796
NM 3196
3198
STX MTX/LTX XLTX
STX MTX/LTX
STX
MTX/LTX
STX MTX/LTX
-20 to 150°F (-29 to 66°C)
0.06
1.52
0.015
0.38
0.005
0.13
0.008
0.20
0.015
0.38
Up to 175°F (79°C)
0.06
1.52
0.015
0.38
0.005
0.13
0.008
0.20
0.020
0.51
Up to 200°F (93°C)
0.06
1.52
0.015
0.38
0.005
0.13
0.008
0.20
0.024
0.61
Up to 250°F (121°C)
0.06
1.52
0.016
0.41
0.032
0.81
Up to 300°F (149°C)
0.06
1.52
0.017
0.44
0.040
1.02
Up to 350°F (177°C)
0.06
1.52
0.019
0.47
Up to 400°F (204°C)
0.06
1.52
0.020
0.50
Up to 450°F (232°C)
0.021
0.53
Up to 500°F (260°C)
0.022
0.56
Up to 550°F (288°C)
Up to 600°F (316°C)
Up to 650°F (343°C)
Up to 700°F (371°C)
Summary of Contents for Goulds Pumps 3196
Page 1: ...Installation Operation and Maintenance Instructions ANSI FAMILY ...
Page 4: ...4 ANSIFAM IOM 12 03 ...
Page 6: ...6 ANSIFAM IOM 12 03 ...
Page 10: ...10 ANSIFAM IOM 12 03 ...
Page 12: ...This Page Intentionally Left Blank 12 ANSIFAM IOM 12 03 ...
Page 28: ...BASEPLATE LEVELING WORKSHEET 28 ANSIFAM IOM 12 03 ...
Page 44: ...44 ANSIFAM IOM 12 03 ...