Programming
PanDoor Installation and Programming Manual
17
Operation
Command
Default
Camera activation
Unit:
Panel
*300 + Y
where:
Y = 0 – Camera off
Y = 1 – always connected
Y = 2 – Powered when off-
hook
(*)
Y = 3 – Powered with any
touch on (**)
(*)
Note
:
Power off will be always with 10
second delay after on-hook.
(**)
Note
:
Power off will be 10 seconds
after the last key has been
pressed.
1
Calling beep
indication
Unit:
Panel
*350+X
Where:
X = 0 no beep indication
X = 1 beep indication
1
Silence time
interval after ring
cycle completion
(20ms resolution)
Unit:
Panel
*362 +XXXX + #
where:
XXXX = Digits (0-9) in msec
Example: 2.5 sec pause =
2500 msec parameter
(PSTN ring silence)
75
Number of rings in
the cycle
Unit:
Panel
*363 +XXXX + #
where:
XXXX = Digits (0-9)
Example: 0025 PSTN ring
Minimum value: 0003
3