background image

 

PanDoor 

Installation and Programming Manual 

 

 

 

Version 1, Release 1.4, August 2008 

Summary of Contents for PanDoor

Page 1: ...ACCESS CONTROL DOOR PHONES PanDoor PSTN Line adaptive Door Access Control Device Installation and Programming Manual...

Page 2: ...PanDoor Installation and Programming Manual Version 1 Release 1 4 August 2008...

Page 3: ......

Page 4: ...that the product proves to be defective in workmanship or materials within a period of one year from date of shipment ITS shall repair or replace the product at its discretion Transportation will be t...

Page 5: ...ds 4 2 Installation 7 2 1 Installing the PanDoor Wall Bracket 7 2 2 Installing the PanDoor Panel 8 2 3 Installing the Controller 10 2 4 LED Indications 12 3 Programming 14 3 1 Programming Code Guide 1...

Page 6: ...e following components Up to two outdoor units available with a keypad and a CALL button allowing visitors to establish a telephone call with an indoor telephone or dial an access code to open a door...

Page 7: ...Introduction 2 PanDoor Installation and Programming Manual Speaker Keypad optional Camera optional Microphone Calling Button Figure 1 PanDoor Panel...

Page 8: ...Introduction PanDoor Installation and Programming Manual 3 1 2 Schematic Setup The following picture illustrates the schematic setup of the PanDoor system Figure 2 PanDoor Schematic Setup...

Page 9: ...with the caller is complete you can either dial a pre defined code to open the door or hang up to terminate the call Opening the door in response to a call from the outside while engaged in conversat...

Page 10: ...Introduction PanDoor Installation and Programming Manual 5 Figure 3 Ring Cycle...

Page 11: ...Introduction 6 PanDoor Installation and Programming Manual This page is intentionally left blank...

Page 12: ...C WIRING INSIDE THE SAME CONDUIT Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line wiring 2 1 Installing the PanDoor Wall Bracket To install the Pa...

Page 13: ...n be installed inside the residence and should be connected to the SW and SW terminals on the PanDoor wire connector Figure 5 illustrates the terminal locations on the wire connector of the outdoor pa...

Page 14: ...g Manual 9 12V 12V CMN N O N C DLR DLR DLR SW SW CCTV CCTV TIP RING 12VDC power input from controller Normally open closed outputs external device Door lock relay terminals Switch terminals Camera pow...

Page 15: ...res to the DLR and DLR terminals 5 If an external bypass switch is installed connect its wires to the SW and SW terminals 6 Place the PanDoor panel onto its mounting bracket 7 If required to install a...

Page 16: ...eypad 1 phone line Keypad 2 phone line 12VDC output to keypad 1 panel 12VDC output to keypad 2 panel 12V battery input optional 13 8V charger input optional TIP RING HOUSE TIP RING KEYPAD 1 TIP RING K...

Page 17: ...2 POWER V and V terminals Note It is strongly recommended to use a 0 8 mm2 cross section wire so that the device will work properly at a distance of up to 100 m 6 Optional Connect the wires of a backu...

Page 18: ...1 2 3 Figure 7 Keypad LEDs Status LED 1 LED 2 LED 3 Idle Off On Off First touch on keypad On On On Code error Fast Blink Fast Blink Fast Blink Door open Slow Blink Slow Blink Slow Blink Timeout to re...

Page 19: ...Panel session 0 switch between PSTN Panel as response to waiting call tone You may modify this code 160 To enter the programming mode 1 Pick up the receiver of the residential telephone and make sure...

Page 20: ...l 900 Hang up Timeout default value 45 seconds Switch to another panel or controller Note It is necessary to hang up between door panel programming and entering a controller 3 1 Programming Code Guide...

Page 21: ...digit already used as Switch Code 160 8 Reset controller to default factory setting Unit Controller 151 Reset panel to default factory setting Unit Panel 152 Panel PSTN Switch Code Unit Controller 160...

Page 22: ...fter on hook Note Power off will be 10 seconds after the last key has been pressed 1 Calling beep indication Unit Panel 350 X Where X 0 no beep indication X 1 beep indication 1 Silence time interval a...

Page 23: ...the Call button is pressed After reaching the specified number of rings the call will be rejected Unit Panel 364 XXXX where XXXX Digits 0 9 in seconds Note Up to 4 digits 20 Change the system adminis...

Page 24: ...he waiting period is a normal operational situation with timeout of 20 seconds This could mean that the person inside the house did not answer the telephone or that he chose not to accept call waiting...

Page 25: ...era is not working Check settings of command 300 When set to 0 camera is disabled When set to 2 camera will be activated only during call or panel touch Check cables wiring Make sure your video equipm...

Page 26: ...F 10 On Hook Impedance 50VDC 40VAC 25Hz 3K Ring Detect 27 100VAC 16 60Hz DC Resistance off hook 24 66VDC 20 100mA 350 Impedance Off Hook 300 3400Hz 500 700 Imbalance Ratio 300 3400Hz 46dB Return Loss...

Page 27: ...Horizontal Frequency 15 625KHz Vertical Frequency 50Hz Total Pixels 542 H x582 V Scanning System 625 lines 50 fields sec CCIR Resolution 420 TV lines horizontal Minimum Illumination 0 5 Lux F2 0 Elect...

Page 28: ...rnal Minimum Illumination 0 5 Lux F1 2 Resolution 380 TVL 470 TVL Enhanced S N Ratio 52dB MIN 60dB TYP AGC OFF White Balance ATW AWB FIX zero color rolling White Balance Range AWB ATW 3200 10000 K FIX...

Page 29: ......

Reviews: