PanCam/Pantel/Pancode Installation and Programming Manual 25
4 Specifications
4.1 General
Specifications
Power Supply (External)
12V [email protected] (supplied with unit)
12-24V [email protected] (optional)
Line Voltage
24-72V DC
DC Leakage
< 10
µ
A
On-Hook Insulation
(Resistance Between Line
Terminal and Ground)
0-100V DC > 5M
Ω
100-200 V DC > 30 K
Ω
500V AC/50Hz > 20K
Ω
100V AC/25Hz > 100K
Ω
Ring Capacitor
0.47
µ
F ±10%
On-Hook Impedance
@50V DC, 40V AC/25Hz>3000
Ω
Ring Detect
27-100 V AC/16-60 Hz
DC Resistance (Off-Hook)
24-66V DC @ 20-100mA/350
Ω
Impedance (Off-Hook)
300-3400Hz 500-700
Ω
Imbalance Ratio
300-3400Hz > 46dB
Return Loss
300-3400Hz > 18dB
Current During Break
< 700
µ
A
DTMF Transmission:
Frequency Tolerance
Frequency Level (High)
Frequency Level (Low)
±1.5%
-6 to –8dBm
-8 to –10dBm
Inter-Digit Pause Time
70-80ms
Relay Switching Current
2A max
Dimensions
Outdoor Unit
Indoor Unit
19.4cm x 10.2cm/7.6inch x 4.0inch
18.5cm x 9.5cm/7.3inch x 9.5inch
Operating Temperature
Outdoor: -20ºC to +50ºC/4ºF to
122ºF
Indoor: 0ºC to +35ºC/32ºF to 95ºF
Summary of Contents for PanCam-C
Page 2: ...PanCam C PanCam T Pantel Pancode Installation and Programming Manual Release 3 May 2003...
Page 12: ...Introduction 8 PanCam Pantel Pancode Installation and Programming Manual...
Page 28: ...Programming 24 PanCam Pantel Pancode Installation and Programming Manual...
Page 32: ...Specifications 28 PanCam Pantel Pancode Installation and Programming Manual...