Installation
PanCam/Pantel/Pancode Installation and Programming Manual 11
Installing the Pantel/Pancode
The Pantel/Pancode can be installed as the individual access
control or can be used with adjacent access-control devices,
such as card reading devices. For more information on
adjacent access-control device installation, see section 2.2,
Adjacent Access Control Device.
A 12V AC external power supply is included with the
Pantel/Pancode unit. A 12 to 24V DC/1.6A power adapter,
which provides a quieter door-lock action, can also power the
Pantel/Pancode. The power adapter should not be located
further than 10m (30ft) from the Pantel/Pancode.
The following figure shows the terminal locations on the wire
connector provided with the Pantel/Pancode. This connector is
attached at the base of the internal component. All wiring to
the Pantel/Pancode is attached to the wire connector.
The Pantel/Pancode supports a bypass switch installation. This
allows opening the door with a hardwired switch. A bypass
switch should be connect to the SW and /SW terminals.
~12V
~12V
N.C.
CMN
N.O.
DLR
~DLR
/DLR
SW
/SW
LINE
LINE
Figure 2-4. Connector Wiring
Note: For the installation of the powered-unlocked-state, use
DLR and ~DLR. For the installation of the powered-
locked-state, use /DLR and ~DLR (this is
recommended for safety purposes).
Power Supply
Normally
Open/Closed
Outputs
Door Lock
Relay
Terminals
Switch
Terminals
Phone
Line/Extension
Summary of Contents for PanCam-C
Page 2: ...PanCam C PanCam T Pantel Pancode Installation and Programming Manual Release 3 May 2003...
Page 12: ...Introduction 8 PanCam Pantel Pancode Installation and Programming Manual...
Page 28: ...Programming 24 PanCam Pantel Pancode Installation and Programming Manual...
Page 32: ...Specifications 28 PanCam Pantel Pancode Installation and Programming Manual...