Programming
20 PanCam/Pantel/Pancode Installation and Programming Manual
OPERATION
COMMAND
DEFAULT
Changing the
Opening door
Access Code
*442 + (New Access
Code)
Access Codes can be up
to four numeric digits.
If the New Access Code
is less than four
numeric digits, press the
# following the entry of
the digits. Allowable
characters are 0 through
9. Do not use the * or #
keys.
Note: The access code
cannot begin with the
same prefix digits as
PBX extension numbers
9876
*For Outdoor
units ONLY
Time between
DTMF’s
*460 + X
where:
X = 1-9
(each step is 200 msec)
2 (400)
Conversation time
limit (sec)
*462 + XX
where:
XX = Seconds (10-99)
00 = Unlimited
45 sec
Door opening
time limit (sec)
*464 + X
where:
X = Number of seconds
(1-9)
3 sec
Changing the
programming
password
*600 + (new password)
Programming access
password must be four
numeric digits.
Allowable characters
are 0 through 9. Do not
use the * or # keys.
1234
*For PanCam-C
ONLY
Camera
instructions
*620 + X
X = 0 camera off
X = 1 camera on
X = 2 camera powered
when call button is
pressed
X = 3 camera powered
when any key is pressed
0
Summary of Contents for PanCam-C
Page 2: ...PanCam C PanCam T Pantel Pancode Installation and Programming Manual Release 3 May 2003...
Page 12: ...Introduction 8 PanCam Pantel Pancode Installation and Programming Manual...
Page 28: ...Programming 24 PanCam Pantel Pancode Installation and Programming Manual...