USER MANUAL 

 

CCA 

370001 

 

ACCESS CONTROLLER

 

 

 

 

 

 

 

 

V02 

Summary of Contents for EKSELANS CCA 370001

Page 1: ...ITS Partner O B S S L Av Cerdanyola 79 81 Local C 08172 Sant Cugat del Vallés Barcelona Spain Phone 34935839543 info ek plus www ek plus USER MANUAL CCA 370001 ACCESS CONTROLLER V02 ...

Page 2: ...amming and Users Management 9 6 1 Numbering user cards 10 6 2 Programming via keyboard remote control 10 6 2 1 Signals when programming the CCA 10 6 2 2 Programming mode via remote control 11 6 2 3 User management via remote control 11 6 2 4 Relay configuration via remote control 13 6 2 5Control signals via remote control 13 6 2 6 Cloning of controllers 14 6 3 Programming via master cards 15 6 3 1...

Page 3: ...e deleting and registering cards selectively activating or deactivating the sound or LED indicators Master cards provide simplicity when registering user cards There is no distinction between cards except their programming For example a master card could be programmed as a user card As explained below it is important to identify each user card with an identifying number Permite alimentar varios ti...

Page 4: ...tage feeding AC DC Entrada Common connector for AC or DC power positive AC Entrada Connector for AC voltage feeding OPEN Right Entrada Connect to the external push button Optional NO Output Relay output Normally open COM Output In Dry Contact configuration Position A Common Port In DC Out configuration Position B Ground Connect to external push button optional NC Output Relay output Normally close...

Page 5: ...pply voltages of the lock and the controller are compatible Especially in the case of using the supply voltage of the controller to feed the lock Jumper in position A Dry Contact See section 4 2 4 1 Controller voltage feeding The controller can be fed both in AC or DC voltage In case of powering the controller with alternating current connect the source to the terminals indicated as AC and AC In c...

Page 6: ...ontact jumper 3 1 It allows the passage of current between an external power supply and the lock It acts as a switch Make sure that the lock supports the power supply voltage of the external power supply This is the factory configuration Position B Direct step jumper in contact 3 4 and 1 2 It feeds the lock with the same voltage that feeds the controller itself It will only work with DC DC A Posit...

Page 7: ...rom position B to position A Attention Install the supplied diode directly in the door opener in the case that it supplies the lock with direct voltage DC Do not use the diode in case of powering the system in AC Respect the polarity of the diode as indicated 5 Installation Below are several typical installations with their connection and configuration Configuration in dry contact the lock opens a...

Page 8: ...a Spain Phone 34935839543 info ek plus www ek plus 8 USER MANUAL CCA Configuration in dry contact the lock opens as the controller opens or closes The controller acts as a switch Configuration in dry contact the lock opens as the controller opens or closes The controller acts as a switch ...

Page 9: ...supports up to 1000 user cards Each of them is registered in the system as they are registered with an identifier 0 1 2 999 Important note It is not possible to know which identifier corresponds to each user card so it is recommended that a record is kept Keeping the registry will allow deleting a user card without physically having it If this is not the case it will be necessary to delete and re ...

Page 10: ...o the serial number of the card and to the user of the card It is not recommended to write down the identifier on the card itself Should it be lost the identifier to be removed from the controller will not be known Identifier Serial Number of the user card Person Department Apartment 0 0093119565 Mr Juan Pérez 1 0093119566 Ms Marta López 999 0093117684 Ms Teresa Monte 6 2 Programming via keyboard ...

Page 11: ...ster code remember it Otherwise it will be necessary to make a factory default reset It must have 6 digits 6 2 3 User management via remote control Each user card is registered with an identifier that matches its position within the system The controller can assign auto incremented identifiers You can also assign a specific identifier Subscribing To add user cards at a position given by the system...

Page 12: ...ep 2 Sweep the card to be unsubscribed This position will be empty 2 Sweep card Step 3 Exit the programming mode Note that a bubble can be been created There can be an empty identifier position not linked with a user card To delete a user card from a specific position The card is lost Step 1 Enter in the programming mode Master code Step 2 Insert the identifier position to be deleted This position...

Page 13: ...5 seconds Step 1 Enter in the programming mode Master code Step 2 Insert two digits that indicate the number of seconds that open the relay 3 1 99 Example Insert 310 for 10 seconds Step 3 Exit the programming mode 6 2 5Control signals via remote control It is possible to enable disable basic signalling indicators By default those are enabled Step 1 Enter in the programming mode Master code Step 2A...

Page 14: ...F NECESSARY The controller may be cloned to another CCA controller The copied data are the configurations of the transmitter controller and the registered user cards Make the following connections Apply the following steps to the unit to clone transmitter Step 1 Enter in the programming mode Master code Paso 2 Start the transfer 9 6 Paso 3 Wait until the transmission ends The green LED blinks Step...

Page 15: ...rcuit between GND and OPEN Otherwise should a push button be connected for opening purposes keep it pressed Step 3 Power on the system again Two sounds will be heard and the LED will change its colour Step 4 Present the two cards on the card reader The first will be coded as MASTER ADD For subscribing The second will be MASTER DELTE For unsubscribing After each card presentation a single sound wil...

Page 16: ...o factory default values The following process restores the original default factory values Registered user cards are NOT lost Registered master cards yes Other values are set back to factory default Step 1 Power off the controller Step 2 Make a short circuit between GND and OPEN Otherwise should a push button be connected for opening purposes keep it pressed Step 3 Power on the system again Two s...

Page 17: ...s 1000 Transmisson protocol card reader controller Wiegand Working voltage Nominal AC V rms 12 30 24 DC Vdc 9 24 12 Consumption Stand by Maximum AC mA rms 115 170 DC mA 60 80 Output voltage For LCA Vdc 12 Maximum switching current A 1 Maximum distance IR Keyboard m 10 Working temperatura ºC 40 60 Working humidity Hum 0 90 Dimensions mm 90 x 63 x 22 Including reader excluding door opener Depending ...