Using a 5-Foot Cable
Water Solutions 60WP Endpoint Installation Guide
29
4.
Twist to align the two tabs.
5.
Install the security seal as shown. Push it until it snaps into place.
NOTE!
For future servicing of either the meter or endpoint, break
the security seal by pulling apart. The original protective connector
covers can be reused if kept clean and dry. Install a new security seal
after servicing either device. To order more parts, see the
Water
Endpoint Ordering Guide
(PUB-0063-001).
IMPORTANT!
Be sure to protect connectors with protective covers.
Do not leave an exposed connector in the field.
Using a 5-Foot Cable
This section describes how to connect the 60WP endpoint to the water meter register using
the 5-foot cable.
To connect the cable to the register
NOTE
The wire terminations must be properly coated with a non-conductive gel
material to prevent water intrusion, or this configuration should not be used in a
pit box environment.