Chapter 2 Installing the 60WP Endpoint
22
Water Solutions 60WP Endpoint Installation Guide
2.
Select a location for the hole that will give sufficient clearance on the bottom side of
the lid to attach the retainer clip collar and cable ties.
3.
Drill a 1 3/4 inch hole in the lid.
NOTE
The O-ring spacers included with the Pit Lid Mounting Kit are not
used with this size hole. You can discard the O-rings.
4.
Insert the retainer clip, or passive radiator antenna, into the hole in the pit lid.
5.
From the underneath side of the lid, place the retainer clip collar around the retainer
clip and snug the collar to the bottom side of the pit lid. Ensure that the top of the
retainer clip is seated against the lid surface as shown below.
6.
Secure the assembly with 2 cable ties (A).
7.
Align and insert the top of the 60WP Endpoint into the offset cavity (A) of the retainer
clip, or passive radiator antenna, and push until it snaps into place.