ITRON 60WP Endpoint Installation Manual Download Page 18

Chapter 2  Installing the 60WP Endpoint 
 

18 

Water Solutions 60WP Endpoint Installation Guide 

 

 

 

Through-Lid Mounting 

This section describes mounting the 60WP Endpoint in a pit lid that has an 1 3/4-inch, 1 
7/8-inch, or 2-inch round hole drilled through it. 

 

 

CAUTION!

 Some pit lids have a molded, recessed cavity that allows Itron 40W-1, 

50W-1, and 50W-2 ERT modules to sit flush with the top surface of the lid. 
However, the dome of the endpoint retainer for the 60-series endpoints, and 
passive radiator antenna, have a smaller diameter and do not fill the pit lid cavity. 
This can make the cavity a trip hazard. Itron does not recommend using this type 
of pit lid with the 60-series endpoints. 

 

 

Pit Lids with Holes 

This section describes how to install the 60WP Endpoint in a pit lid that already has a 1 3/4-
inch, 1 7/8-inch or 2-inch hole in the lid. The Pit Lid Mounting Kit or the Passive Radiator 
Antenna Kit can be used for this application. This section will explain how to install both 
types of kits. Please refer to publication PUB-0771-010 for guidance on which kit to install 
for different pit lid material and traffic conditions. 

 

NOTE

  For lids that require a hole to be drilled, see 

To install in new lids

 on page 

21. 

 

 

Required Tools and Hardware 

 

Pit lid mounting kit (Itron part number CFG-0771-010) or passive radiator antenna kit 
(Itron part number CFG-0771-006) 

 

Cable tie gun 

 

 

NOTE

 The pit lid mounting kit is not intended for applications involving 

vehicular traffic. The passive radiator antenna should be used in incidental traffic 
areas, such as residential environments. 

 

 

Summary of Contents for 60WP Endpoint

Page 1: ...Water Solutions 60WP Endpoint Installation Guide Water Solutions...

Page 2: ...erating transmitters and receivers and cannot be shipped by air All product returns must be shipped by ground transportation Repairs and Modifications WARNING Attempts to repair this device by unautho...

Page 3: ...on 11 Wall Mount Installation 16 Required Tools and Hardware Wall Mount Installation 16 Installing Using a Wall Mount 16 Through Lid Mounting 18 Pit Lids with Holes 18 Required Tools and Hardware 18 I...

Page 4: ...Contents iv Water Solutions 60WP Endpoint Installation Guide...

Page 5: ...antly reduced as the meter is located deeper in the pit box When a point is reached where read reliability is compromised a new installation method must be selected How This Document is Organized This...

Page 6: ...Overview on page 10 for a diagram of the installation process WARNING This type of note is used to warn of potential physical harm to the user or hardware It is critical that you pay strict attention...

Page 7: ...riod will be reset Tamper Indicators To minimize the possibility of theft the 60WP Endpoint features cut cable tamper reporting as well as a security seal to indicate physical tampering A cut cable ta...

Page 8: ...tays in Programming Mode for 15 minutes For the location of the magnet see Activating Programming Mode on page 31 NOTES Hold the magnet in position for three seconds to activate Programming Mode If it...

Page 9: ...over for inline connector and tamper seal for security ERW 0771 301 Figure 1 OR 60WP endpoint with a 5 foot cable ERW 0771 311 Figure 2 NOTE The 6 inch cable variant is only available to meter manufac...

Page 10: ...r pit box environment Use Panduit PLT4H 76 or equivalent cable ties for outdoor and pit box applications Through Lid Mounting kit Itron part number CFG 0771 010 Minimum order 36 Shelf Mount Adaptor It...

Page 11: ...od material see information under Compatibility Chart at the following Itron website address www itron com pages products_detail asp ID itr_000428 xml pgtype subID ar WARNING You must ensure that the...

Page 12: ...Guide The following figure shows a bottom view of the rod mount The 1 2 inch diameter rod hole is indicated in the photo Figure 3 Rod Mount Bottom View The following figure shows a side view of the r...

Page 13: ...re longer rod lengths to ensure the endpoint is well supported and remains vertical 4 Without touching the meter body or adjacent pipes position the rod as close to the center of the pit as possible a...

Page 14: ...the rod making sure the rod is completely seated into the Rod Mount hole of the endpoint The endpoint should slide freely onto the rod it should not be forced 7 When the installation is complete the e...

Page 15: ...Mount Installation Water Solutions 60WP Endpoint Installation Guide 15 CAUTION If the endpoint module installation is too high too low or touching any of the surrounding surfaces then adjust as necess...

Page 16: ...ead screw that is appropriate for the type of box material Installing Using a Wall Mount To install the 60WP Endpoint using the wall mount method mount the endpoint on the pit box wall so that the top...

Page 17: ...oint housing 6 Keeping the 60WP endpoint in the upright position drill the second pilot hole using the bottom mounting hole as a template NOTE If using a screw anchor mark the location of the bottom a...

Page 18: ...t Lids with Holes This section describes how to install the 60WP Endpoint in a pit lid that already has a 1 3 4 inch 1 7 8 inch or 2 inch hole in the lid The Pit Lid Mounting Kit or the Passive Radiat...

Page 19: ...e diameter of the hole in the pit lid If the hole diameter is 1 3 4 inch an O ring spacer is not required 3 For 1 7 8 inch or 2 inch holes place the appropriate O ring spacer over the pit lid mounting...

Page 20: ...Endpoint into the offset cavity A of the retainer clip or passive radiator antenna and push until it snaps into place The finished assembly is shown below Installing Through New Lid This section descr...

Page 21: ...n part number CFG 0771 006 Cable tie gun NOTE The pit lid mounting kit is not intended for applications involving vehicular traffic The passive radiator antenna should be used in incidental traffic ar...

Page 22: ...s size hole You can discard the O rings 4 Insert the retainer clip or passive radiator antenna into the hole in the pit lid 5 From the underneath side of the lid place the retainer clip collar around...

Page 23: ...elf mount adaptor to mount the endpoint in a pit lid slot IMPORTANT The pit lid and slot must have the correct dimensions for the 60WP assembly to fit properly The following illustration and the accom...

Page 24: ...lowing tools and hardware are required when installing the 60WP Endpoint using a shelf mount adaptor for a pit lid slot Shelf Mount Adapter Itron part number CFG 0771 007 A Foam spacers To install usi...

Page 25: ...assembly into the pit lid with the foam spacers positioned on each side of the pit lid slot Figure 6 Correct Position With Foam Spacers on Each Side of Slot A Correct position for foam spacers IMPORT...

Page 26: ...7 Wrong Position for Spacers Spacers are not supported A Unsupported foam spacer 4 The installed position of the endpoint should be vertical and upright when the lid is replaced on the pit IMPORTANT...

Page 27: ...inline connector assembly Follow the manufacturer s recommended procedure for installing the water meter register on the meter To connect the inline connector NOTE Skip this step if an inline connecto...

Page 28: ...install the endpoint Any of the three pins are damaged or missing The O ring is missing The cable is cut or nicked 2 Connect the endpoint to the register cable connector Holding the connectors by the...

Page 29: ...curity seal after servicing either device To order more parts see the Water Endpoint Ordering Guide PUB 0063 001 IMPORTANT Be sure to protect connectors with protective covers Do not leave an exposed...

Page 30: ...White G Black R Using an Extended Cable If you need to extend the length of the existing endpoint cable up to a maximum of 300 feet additional cable can be ordered from Itron For cable lengths exceed...

Page 31: ...ndlheld device Activating Programming Mode Use the programming magnet Itron part number MLD 0175 001 to place the endpoint into Programming Mode Place the magnet on top of the Rod Mount Hole A as show...

Page 32: ...aced in the Quite Mode For more information see Operating Modes on page 8 Programming the 60WP Endpoint To program a 60WP Endpoint use an FC200SR handheld running the Itron Endpoint Link or Endpoint L...

Page 33: ...ing the 60WP Endpoint Water Solutions 60WP Endpoint Installation Guide 33 The correct position for programming the endpoint is shown below Figure 12 Programming the 60WP Correct Position for Handheld...

Page 34: ...dheld computers to verify consumption G5R FC200R FC200SR NOTES Each handheld radio requires special setup and configuration parameters to successfully read and program 60 series products Refer to the...

Reviews: