Installing Fan Heaters
5.1 Before You Begin
ITR makes a variety of 12 VDC fans for heating separate or
combined areas:
Small Space Cabin Fan (6095) - 0.5 Amp., 4000 BTU/h.
Low-Profile Cabin Fan (6132) - 1 Amp., 6000 BTU/h.
Standard Cabin Fan (6002) - 0.9 Amp., 8700 BTU/h.
High Output Cabin Fan (6093) - 1.6 Amps., 12000 BTU/h.
Defrost fan - 10 Amps., 20,000 BTU/h. This fan comes with a
3-speed switch. The maximum fan speed draws 10 Amps.
For best results, the fans should be mounted as close to the
floor as possible. It is recommended that an individual
temperature sensor (aquastat) be installed on the fans to
prevent the fan from blowing cold air while the heat transfer
fluid is being heated by the burner. (Refer to Sec. 5.2-
Features and Fig. 5.1 Wiring the Fan’s Aquastat)
Note: The total number of heating fans used with the
Oasis® Zephyr™ HW is limited by combined BTU
output and fan current draw
Only the installation of ITR fan heaters is covered in this
Manual. Prior approval from ITR is required if non-ITR
heating fans are installed. Total fan amperage draw must be
compatible with the Zone Control Board. Also, flow capacity
of the heating fans must meet system requirements.