Section 2, Mounting the Heater Unit
2-2
Installation Manual for
Oasis
® Zephyr™ HW Heating
2.2 Mounting Location
·
Mounting location must be able to support double the gross
weight of the heater when full (i.e.70 lbs. x 2 = 140 lbs./63.5
KG) and must be of a non-combustible material.
·
The Oasis
®
Zephyr™ HW model is 10.5”H x 14” W x 19” D
(26.6 cm x 35.5 cm x 48.2 cm). See Figure 2-1: Dimensions
The Oasis® Zephyr™ HW heater must not be installed in any
compartment with flammable gases.
·
The Oasis® Zephyr™ HW heater must be isolated completely
from all living spaces. Combustion air must be drawn directly
from an outside source and cannot contain any combustible
gases. Use the supplied air intake hose (part#8019) and the
aluminum air intake collar (part#10089). Securely clamp and
seal all air inlet hose connections. Ensure the supply of
combustion air to the appliance is not obstructed or cut off.
·
The heater must be mounted in an area that provides
unrestricted access to the front panel, top access panel and
access to fuel, water, power and exhaust connections. There
should be at least 12” of clearance on the top of the heater for
accessing and servicing the components and water
temperature adjusting valve. Available space for connection to
the rear of the heater is necessary if vehicle engine heat
management is connected to the Zephyr. There should be at
least 1” clearance to all other Oasis® Zephyr™ HW heater
surfaces.
·
The heater must not be installed in any compartment with
flammable gases.
·
The heater must be mounted horizontal and level using the
two included mounting brackets that bolt to the side of the
heater.
DANGER