22
HBV-609 Technical documentation
Forcible RUN
Forcible STOP
Ready to
Receive
Forcible RUN
Forcible STOP
Ready to
Receive
6-5.
HBV-609
connector details
■
Sensor signal type is selectable PNP or NPN.
This signal change effect the type of all the other input signals all at once.
■ ※
1 The roller will be forcibly run when set as host control mode
(SW5#0), regardless of SW2#3 and #4 setting.
■
Output sensor signal when detecting a product on the conveyor.
■
It is common with MDR power supply.
■
The communication cable is an optional accessory.
(
Use the communication cable which is category 5e or more.
)
Power connector
:
CN1
MDR
connector
:
CN101
、
CN201
Sensor connector
:
CN301
、
CN401
Communication cable
connector
:
CN302
、
CN402
2
1
1
2
+
24V
0V
No.
Function
3
1
CN101
:
Motor A
CN201
:
Motor B
Control connector
:
CN4
6
1
1
Error signal output from CN4#4 is stopped and LED indication is reset by signal ON.
The roller is run to CW direction seen from the installed driver card side by signal OFF.
The roller is run to CCW direction seen from the installed driver card side by signal ON.
Motor A is forcibly run by signal input.
2
Motor A is forcibly stopped by signal input.
3
4
5
6
If Motor A is at a downstream end, the product is discharged by signal
ON when zone sensor of Motor A is ON.
Pulse signal depending on each error type is output when error is occurred.
(Discharging at error condition)
Error signal is output when error is occurred. (Discharging at error condition)
Output a signal when Motor A is turned ON.
Output a zone sensor signal of Motor A.
Output a signal when Motor B is turned ON.
Output a zone sensor signal of Motor B.
No.
Error reset
Transfer direction
(DIR)
Error output
Function
SW1#1 ON
SW1#1 OFF
SW2#3 ON
SW2#3 OFF
SW2#4 ON
SW2#4 OFF
SW1#8 ON
SW1#8 OFF
SW2#1 ON
SW2#1 OFF
SW2#2 ON
SW2#2 OFF
SW setting
Description
PLC side
※
1
※
1
※
1
Motor B is forcibly run by signal ON.
Motor B is forcibly stopped by signal ON.
※
1
※
1
※
1
If Motor B is at a downstream end, the product is discharged by signal
ON when zone sensor of Motor B is ON.
※
1
※
1
※
1
※
1
Signal
output
Signal
input
1
2
+
24V
Sensor input
3
0V
No.
Function
M8 5P connector
0
9
8
7 6 5 4
3
2
1
0
9
8
7 6 5 4
3
2
1
0
9
8
7 6 5 4
3
2
1
0V
SEN
24V
SensorA
Port
Power
A
Port
B
24V
SEN
0V
SensorB
SPEED
SET A
TIMER
SET
SPEED
SET B
1 DIR/RST 2 AUT
O/MANU
3 NPN/PNP
OUT
4 ZP2/ZP1 5 DIRCTION
A
6 DIRCTION B 7 ZONE 2/1 8 ERR ON/PLS
1 SEN/SYN
A
2 SEN/SYN B 3 ST
OP/RUN
A
4 ST
OP/RUN B
PWR
OUT B
OUT A
ERR
INPUT B
INPUT A
DIR/RST
I/O
CTRL
SEN A
SEN B
0V
24V
HBV-609F□
STS
A
MOT
A
B
STS
MOT
B
MOTOR
B
MOTOR
A
CN302
CN301
CN1
CN402
CN4
CN401
MOTOR B
SW1 SW2
SW3 SW4
SW5
MOTOR A
CN201
CN101
HBV-609 Function list and Wiring
Safety precautions
Advance preparation
Check Product
Installation/Wiring
Maintenance/Inspection
noi
tar
ep
O/l
ort
no
C
sn
oit
aci
fic
ep
S
6. Installation/Wiring
Motor A
Motor A
Motor B
Motor B
Synchronization
output
Sensor
output
Synchronization
output
Sensor
output
Original notice - U1.4