Specifications subject to change without notice
ITOH DENKI USA, INC
135 Stewart Road
rev15-0615
PH: 570-820-8811
Hanover Industrial Estates
FX: 570-820-8838
Wilkes-Barre, PA 18706-1462
Page 5 of 26
Connections
(continued)
Input / Output settings CN4
CN4-1 – Direction / Error reset (selectable by SW1-1; see page 11)
•
Direction input (SW1-1; OFF) [Default]
o
Reverses the logic flow and motor direction while the input is active. Logic flow is independent of motor
direction.
o
This signal is shared through the communication cable.
•
Error reset input (SW1-1; ON)
o
Resets error conditions at the time the signal is input only when the card is in operational condition and
causes of errors have been removed. This signal is shared through the communication cable.
o
CN4-2 – Input A (selectable by SW2-3; see page 12)
•
Forcible run motor A input (SW2-3; ON) [Default]
o
Forcibly runs motor A while signal is active
•
Forcible stop motor A input (SW2-3; OFF)
o
Forcibly stops motor A when sensor A becomes blocked while signal is active
CN4-3 – Input B (selectable by SW2-4; see page 12)
•
Forcible run motor B input (SW2-3; ON) [Default]
o
Forcibly runs motor B while signal is active
•
Forcible stop motor B input (SW2-3; OFF)
o
Forcibly stops motor B when sensor B becomes blocked while signal is active
CN4-4 – Error output (selectable by SW1-8; see page 11) [25mA maximum]
•
Pulsed output (PLS; ON)
o
Used when connecting the error output to an IB-E03 / 04 remote input 1 (CN301-1 on IB-E series)
PNP pulse with SW2-3 ON
NPN pulse with SW2-3 OFF
•
Output signal (ERR ON; OFF) [Default]
o
Outputs a signal when an error occurs
PNP signal with SW2-3 ON
NPN signal with SW2-3 OFF
CN4-5 – Output A (selectable by SW2-1; see page 12) [25mA maximum]
•
Synchronous output (SYN A; SW2-1 ON) [Default]
o
Outputs a signal on CN4-5 when motor A runs
•
Sensor output (SEN A; SW2-1 OFF)
o
Outputs a signal on CN4-5 when sensor A is blocked
CN4-6 – Output B (selectable by SW2-2; see page 12) [25mA maximum]
•
Synchronous output (SYN B; SW2-1 ON) [Default]
o
Outputs a signal on CN4-6 when motor B runs
•
Sensor output (SEN B; SW2-1 OFF)
o
Outputs a signal on CN4-6 when sensor B is blocked