![ITOH DENKI POWER MOLLER HBL-606FN Technical Document Download Page 17](http://html1.mh-extra.com/html/itoh-denki/power-moller-hbl-606fn/power-moller-hbl-606fn_technical-document_2095760017.webp)
Specifications subject to change without notice
ITOH DENKI USA, INC
135 Stewart Road
rev15-0615
PH: 570-820-8811
Hanover Industrial Estates
FX: 570-820-8838
Wilkes-Barre, PA 18706-1462
Page 17 of 26
LEDs and Error Indications (Continued)
LED
Green
Orange
Red
ERR Signal
(CN2-5)
Cause
Effect
Solution*
STS A
○
(OFF)
-
○
(OFF)
○
(OFF)
Not told to run
Normal
-
●
(ON)
-
○
(OFF)
○
(OFF)
Told to run
Normal
-
○
(OFF)
-
Blinks (6Hz)
●
○
●
○
●
○
●
○
●
○
●
○
●
(ON)
Fuse blown or
low voltage
No operation
1
○
(OFF)
-
Blinks (1Hz)
●
○
●
(ON)
Motor is not
connected to card
No operation
2
●
(ON)
-
Blinks (1Hz)
●
○
●
(ON)
Motor locked
≥
1s
No operation
3
○
(OFF)
-
●
(ON)
●
(ON)
Thermal protection
No operation
4
●
(ON)
-
Blinks (6Hz)
●●
○○○○
●●
○○○○
●
(ON)
Back EMF
Dynamic
brake
5
STS B
○
(OFF)
-
○
(OFF)
○
(OFF)
Not told to run
Normal
-
●
(ON)
-
○
(OFF)
○
(OFF)
Told to run
Normal
-
○
(OFF)
-
Blinks (6Hz)
●
○
●
○
●
○
●
○
●
○
●
○
●
(ON)
Fuse blown or
low voltage
No operation
1
○
(OFF)
-
Blinks (1Hz)
●
○
●
(ON)
Motor is not
connected to card
No operation
2
●
(ON)
-
Blinks (1Hz)
●
○
●
(ON)
Motor locked
≥
1s
No operation
3
○
(OFF)
-
●
(ON)
●
(ON)
Thermal protection
No operation
4
●
(ON)
-
Blinks (6Hz)
●●
○○○○
●●
○○○○
●
(ON)
Back EMF
Dynamic
brake
5