General Specifications
PcOS Series 90PLUS
Programmer's Guide
Page 14
Rev M
12/16/99
3.6.2.2
Validation Forms Sensing
The printer has a sensor that is used to detect the presence of a validation form. This sensor may be
queried by an application to check on the presence of a form. It is located approximately 0.5 inch
(12.7 mm) below the print line and to the far right of the paper path.
3.6.3
Inserted Forms Printing
Top of form to top of print line
0.06 inch (1.52 mm)
Minimum form length
3.375 inches (85.7 mm)
Minimum form width
2.5 inches (63.5 mm)
Bottom of form to bottom wire
0.625 inch (15.9 mm)
3.375 - 11.00”
(85.7 - 279.4 mm)
2.40”/2.80”
(61.0/71.1 mm)
2.50 - 9.00”
(63.5 - 228.6 mm)
0.50” (12.7 mm)
0.06”
(1.52 mm)
0.625” (15.9 mm)
Figure 10 Inserted slip using normal and narrow print zone