Cause

.

Solution

Travel monitor
1. The table could be jammed or overloaded.
2. A motor is incorrectly connected to the control 

system.

1. Remove the load and move the table a short distance 

in the opposite direction.
2. Check the plug connection and RESET the system 

(see 6.1).
If the error persists, contact your service partner.

Faulty motor signal

Check the plug connections of the columns. It may be 

necessary to replace the control system or columns.  

Replace the parts or contact your service partner.

Motor not recognised
Check the plug connections.  

If the error persists, the column or control system is 

defective.  

Replace the parts or contact your service partner.

On-time limiter/overheating protection

The electronic system monitors how long the drives 

have been running. If the maximum permissible time is 

exceeded, the electronics will not permit the drives to be 

run any longer.  

This protects the power pack, control system and drives 

against overload.

Overheating: 

The control system has exceeded the permitted 

temperature.

You must wait until the transformer has cooled down. How 

long this will take depends on the ambient temperature.

Overcurrent in drive: 

One or more drives are overloaded.

Check the permissible load for the table in the installation 

guide. 

Remove the cause of the overload. Check that the table 

has been properly assembled and is free from strain.  

If the error persists, contact your service partner.

Short circuit –  

manual controls connection

Check the connections. The control system or the manual 

controls may be faulty.  

Replace the faulty part.  

If the error persists, contact your service partner.

Short circuit –  

motor connection

Check the connections. The control system or the guiding 

column may be faulty.  

Replace the parts.  

If the error persists, contact your service partner.

Control system faulty

Replace the control system or contact your service 

partner.

Reset – compulsory

Please RESET the system (see 6.1).

Movement lock engaged

Press the “M” button for 10 seconds.

A CA

A C9

A D7

A 6F

A 70
A 71

A 72
A 73

E DE 

E E9

If the manual controls display a fault code that is not listed in the table, contact the manufacturer.

A65

A64

E D4 

E D7

E 6A

8. Error messages on the manual controls

Summary of Contents for Work bench 4 E FIFO

Page 1: ...User guide Work bench E 4 E and 4 E FIFO...

Page 2: ...ight adjustable work bench 8 4 1 Environmental considerations 8 4 2 Levelling the work bench 8 5 Electrical connections for height adjustable tables 9 6 Start up 10 6 1 Initialising the table columns...

Page 3: ...they can be easily accessed by all users Observe the directions contained in the main user guide for a system The general safety information applies to the entire lifecycle of the electrical height ad...

Page 4: ...responsible for ensuring proper and safe installation You have carefully read and understood the installation guide You are appropriately qualified You are mentally and physically capable of doing so...

Page 5: ...5 1 5 CE declaration...

Page 6: ...nch 4 E An electrical height adjustable work bench incorporating a control system with a memory function For applications where exceptional stability and load carrying capacity are essential The table...

Page 7: ...ons a x b mm plastic coated s 25 mm high pressure laminate s 30 mm high pressure laminate ESD s 30 mm beech multi ply s 40 mm Upright Overhang Upright required Cable Duct E Upright required 1200 x 600...

Page 8: ...ou will need the following tool Spirit level Faults may occur as a result of incorrect set up or start up The height adjust able work bench may be damaged and the service life may be shortened When se...

Page 9: ...ed damp rooms on or near highly flammable materials or near high frequency devices e g transmitters radiation emitting devices or similar equipment Ensure that connecting cables and electrical lines a...

Page 10: ...and shorten the service life During initialisation RESET do not restrict the movement of the table columns by means of any mechanical connection The connected table columns need to be initialised RESE...

Page 11: ...per ated at reduced speed briefly after they are started before they are stopped 7 4 Soft start soft stop The drives are operated at reduced speed briefly after they are started before they are stoppe...

Page 12: ...l limit re enter setting mode by pressing the M button eight times When the audible signal indicates that setting mode is active move the table columns through the entire adjustment range right up to...

Page 13: ...the permitted temperature You must wait until the transformer has cooled down How long this will take depends on the ambient temperature Overcurrent in drive One or more drives are overloaded Check th...

Page 14: ...he power supply Put in place suitable measures to prevent the power supply from being switched back on unintentionally Use only original spare parts The materials used are environmentally friendly The...

Page 15: ...15 12 Annex 12 1 Declaration of incorporation for the table columns...

Page 16: ...y Date www item24 com 0 4 119 25 12 2013 Made in Germany Workbench type 4 E FIFO AB No Input 230V 50Hz 2 7A Duty cycle 10 2min 18min Maximum load 4000N Serial number Control Unit Serial number Table C...

Reviews: