Archimede 5000 series- FM Power Amplifiers
User’s manual – Page 38 of 65
2)
The read-only
Analog Inputs
menu
will show. It’s split in three pages and lists the results of internally carried out
measurements:
Forward Power
: forward output power level
Input Power
: driving input power level
Reflected P.
: reflected power level
BIAS Volt
:
bias voltage.
In stand-by mode the
BIAS Volt
value is
NEGAT
(negative), whereas during the normal operation it will be a voltage value
Heatsink T. C
: temperature of the amplifier section heatsink (in °C)
Ambient T. C
: environmental temperature (in °C).
Main Voltage
: power supply voltage of the MOS FETs
Module Curr. 1
: current of the amplifier module # 1
Module Curr. 2
: current of the amplifier module # 2
Module Curr. 3
: current of the amplifier module # 3
Module Curr. 4
: current of the amplifier module # 4 (only with Archimede 4000 and Archimede 5000).
To quit and go back to the
Debug Page
, press the knob.
10.5.b
Logic Inputs
menu
This menu allows to check the proper operation of the
ON/STAND-BY
button by checking its dedicated contacts of the control board.
Moreover, it shows the presence of an external stand-by command coming from the
REMOTE
connector [14]. Finally, it shows if one
or more alarms are currently released (
1)
From the
Debug Page
(
Logic Inputs
.
2)
Press the knob. The
Logic Inputs
page will be shown (see bottom note):
Start Button
: proper operation of the
ON/STAND-BY
button. It is tested on the related contacts in the CPU board (in order
to also test the wirings). When pressed,
OFF
changes into
ON
standby
: in case of an active stand-by command, you will see
ON
(alarm name) - if one or more alarms are currently released it/they will be shown from this line (see bottom note)
3)
To quit and go back to the
Debug Page
, press the knob.
If one or more alarms will be released, they will be displayed from the 3
rd
line, so the
Logic Inputs
page could be eventually
split in two ones in order to make sufficient room to accommodate the alarm(s). To scroll the alarms, simply turn the knob
counterclockwise.
Summary of Contents for ARCHIMEDE 5000 Series