Archimede 5000 series- FM Power Amplifiers
User’s manual – Page 15 of 65
When installing Archimede 5000 or Archimede 4000 models make sure to earth the equipment through the ground
wire of the power supply cable (
[16]
Power Supply cable
– Archimede 3000 standard model can be connected to a single-phase 230V
AC
power line. Archimede
4000 can be connected to a single-phase 230V
AC
, to a three-phase 220V
AC
or to a three-phase with neutral wire 400V
AC
power
line.
For details about the Archimede 4000 power supply connections
On demand, Archimede 3000 can be supplied for the connection to a three-phase with neutral wire 400VAC power line
[17]
RF OUT
(50 OHM)
–
an FM broadcasting suitable antenna able to bear the amplifier rated power must be connected to this
flange.
Archimede 3000
is default supplied with a 7/16 connector. On demand, it can be supplied with a 7/8 flange.
Archimede 4000
and
Archimede 5000
are default supplied with a 7/8 flange complete with a 7/8 rigid line flange. This is a
quite useful solution when carrying out maintenance operations (e.g.: fans maintenance), because i
t’s not necessary to
unsolder the 7/8 rigid line connector, being sufficient to loosen a clip to get the equipment free and removable from the rack
(clearly after having removed all the other connections).
[18]
Power ON/ OFF
–
it enables to switch on/off the equipment (main power supply).
[19]
RF IN
– The exciter must be connected to this N type connector.
Do not exceed the maximum driving input power levels given in the following table:
Maximum Driving Input Power levels
Archimede
3000
Archimede
4000
Archimede
5000
35W
50W
60W
[20]
INTERLOCK AUX
– when installing Archimede 3000 or Archimede 4000 connect the power supply input of the exciter to this
VDE female connector.
This solution acts as an interlock command managed by the amplifier control board which can decide, in case of an active
critical alarm, to switch off the exciter.
[21]
Power supply cable
– Archimede 5000 comes with a 7 x 1.5 mm
2
(six poles + neutral wire) power supply cable, about 2
meters long.
Archimede 5000 can be connected to a single-phase 230V
AC
, to a three-phase 220V
AC
or to a three-phase with neutral wire
400V
AC
power line.
For details about the Archimede 5000 power supply connections