18
INSTALLER
COVER THE MODEL
Install the device without the use of cement
or other adhesives for the building that may
prevent the eventual removal.
The Ductwork coating, all self-supporting,
complete the installation of this device and
must be constructed of nonflammable material in
full compliance with the regulations.
Unlike other similar products on the market, this devi-
ce makes it possible to bring the coating Ductwork (1)
in direct contact with the frame (9).
installation
- Check the tightness of the pipes and gas fittings;
- Check the tightness of the flue;
- Check the electrical connections (if any);
- Verify the correct operation of the Device;
- Bring the flush finish of the frame (9);
SAFETY
This device has two safety devices:
- Atmosphere sensing device (1)
- Thermocouple (2)
Atmosphere sensing device
Based on measured air quality, this device turns off
or prevents re-ignition of the Device. Under the test
conditions according to EN, this device sensitive to
the atmosphere, intervenes before the CO concen-
tration in the environment, is greater than 200 x 10 -6
(V / V).
Thermocouple
In case of accidental extinguishing of the flame or
sudden lack of gas supply, this device provides the
immediate closure of the valve off and then the
Device.