Switch-off
• Switch off the appliance: turn the control knob
clockwise and return to “
PILOT
” position.
• To switch the appliance off definitively (prolonged
period without use): turn the control knob clockwise
as far as “
PILOT
” position.
After reaching this position, press the control knob
and turn it to “
OFF
” position.
Close the gas supply tap.
REMOTE CONTROL UNIT
Ignition
• Open the gas supply tap.
• Press the switch (5) of the gas valve in “
I
“ position.
• Make sure the knob (7) of the manual operation
mechanism is positioned on “
ON
”.
• Point the remote at the device and simultaneously
press the "
SPARK
" and "
Triangle ON
" on the sup-
plied remote.
• An acoustic signal will indicate the start of the start
sequence. The electronic system checks correct gas
flow and ignites the main burner (these operations
could take up to 20 seconds). After burner ignition,
the flame automatically positions on maximum.
If the pilot flame goes out, wait at least five
minutes before repeating the described ope-
ration. During the start phase, the knob of the
manual operation mechanism must be on “ON”.
Operation
Setting the code
: is selected automatically between
65000 codes. The receiver (at the edge of the chim-
ney) must know the remote control code:
- Press and hold the RESET button of the receiver in
the fireplace until you hear two (2) beeps: the first is
short and the second is long. After the second beep,
release the RESET button.
- Within the next 20 seconds, press the button (small
flame) on the remote until you hear two short beeps,
which further confirm the correct setup code. If you
hear one long beep, the acquisition sequence code
failed or the wiring is incorrect.
This setting is performed only once and is
not required after changing the batteries on
the remote or receiver.
Once the Appliance has been switched on,
the Manufacturer suggests leaving it run-
ning for 10 minutes at max output, before making
any adjustments.
At minimum, the burner remains off, leaving on only
the pilot flame.
From minimum position, the output can be turned up
without repeating the ignition operation.