1.
Short press the binding key once (less than 3 seconds)
.
2. The permit join is now enabled for 60 seconds and the indicator light will flash 60
times.
3. SGZA10 waits the new device to join in automatically. Please note that the maximum
waiting time to join is 60 seconds. Repeat the process if you missed the 60 seconds
period. Within the 60 seconds, short press the binding key when you want to disable
the permit-join finction.
Restore to factory setting
SGZA10 is capable of storing and saving includes network routing information. If you wish
to remove SGZA10 from the network and join to a new network, you would need to clear
the setting by simply reset the device to restore to the factory setting.
Operation:
Step 1.
First remove the power from the device
Step 2.
Hold on to the binding key. While doing so, power up the device again to give
power, until the
indicator light flashes quickly
then release the key. If you want the
keeper to be a gas keeper then go to Step 4 instead of 3 because
by default SGZA10 is a
gas keeper
. But to program the keeper as water keeper then go to Step 3.
Step 3. To configure SGZA10 as water keeper,
while the indicator is flashing quickly
from Step 2,
short press the binding key once
. This will configure it to become a
water keeper. Now go to Step 4.
(To make the device as a gas keeper, you should skip this step and go to step 5)
Step 4.
Now the device is restored to the factory setting. Now power cycles the device to
put the device into network search mode.
(Note: by default SGZA10 is a gas keeper)