background image

Indicator LED 

Binding key 

Manual lever releaser 

Lever 

Power receptor 

 

Installation holder 

Gas / Water Keeper

 

SGZA10

 

 
 
 
 
 
 
 
 

 

Other ISysmart related devices 

Switch controller: 

 Multiple/Scene controller SGZ503 

 Smoke detector SGZA01A/B/C/D 

Summary of Contents for SGZA10

Page 1: ...Sysmart i ZigBeeTM Gas Water Keeper User Manual Gas or Water Keeper Model SGZA10 ...

Page 2: ...ED Binding key Manual lever releaser Lever Power receptor Installation holder Gas Water Keeper SGZA10 Other ISysmart related devices Switch controller Multiple Scene controller SGZ503 Smoke detector SGZA01A B C D ...

Page 3: ...A10 s operating pressure is 7 kgf Valve rotation angle is 90 What is ZigBee ZigBee is a short range wireless transmission technology which defined for a minimum complexity low power consumption low data rate cost effective wireless solution ZigBee lies in between wireless markup technology and Bluetooth ZigBee is based on IEEE806 15 4 standard the mutual co ordination between thousands of sensors ...

Page 4: ...If it is a water keeper it will receive on or off instruction from a remote controller by the user Step 2 Power up the device and network association To allow SGZA10 to function it must first join to a ZigBee network either through a coordinator or a router device When it is given power it will automatically start searching for an existed network So before you give power to SGZA10 make sure it is ...

Page 5: ...rollable device which receive command signal from a zone device i e upon receive a smoke alarm it changes the position of the leaver So pair SGZA10with a smoke gas detector As a water keeper the device can be controlled wirelessly from a paired remote controller So pair SGZA10 with an On Off remote controller The pairing operation is the same for both types except for the types of device to pair w...

Page 6: ...0 is configured as a gas keeper On the fire event the paired device sends command to gas keeper and brings the lever to down position Manually release the lever lock button by pushing it inwards to release the lever so you can move the lever either up or down NOTE When the Manual Lever Releaser Button lever lock button keeps inwards as the figure below please slightly move the lever to release the...

Page 7: ...ice to restore to the factory setting Operation Step 1 First remove the power from the device Step 2 Hold on to the binding key While doing so power up the device again to give power until the indicator light flashes quickly then release the key If you want the keeper to be a gas keeper then go to Step 4 instead of 3 because by default SGZA10 is a gaskeeper But to program the keeper as water keepe...

Page 8: ... Commissiong 0x0015 Attributes of the Basic Device Information attribute set Identifier Name Type Range Access Default Mandatory Optional 0x0000 ZCLVersion Unsigned 8 bit integer 0x00 0xff Read only 0X03 M 0x0001 ApplicationVersion Unsigned 8 bit integer 0x00 0xff Read only 0X0E O 0x0002 StackVersion Unsigned 8 bit integer 0x00 0xff Read only 0X2E O 0x0003 HWVersion Unsigned 8 bit integer 0x00 0xf...

Page 9: ... 16 bytes Read only 20130122 O 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0X04 M 0x0010 LocationDescription Character string 0 16 bytes Read write O 0x0011 PhysicalEnvironment 8 bit Enumeration 0x00 0xff Read write 0x00 O ...

Page 10: ...n a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and circuitry This may shorten the life span of the device damage the battery and cause the housing to deform Do not throw or strongly vibrate the device This may damage connectivity of the electronic par...

Reviews: