AW16000 - Instruction Manual
The dust collector access doors and dust drawer on the reclaimer must be closed when the dust collector is on.
CAUTIOn
: do not pulse new dust collectors or replacement cartridges until the cartridges are properly seasoned.
Pulsing unseasoned cartridges could cause premature cartridge failure or decrease the efficiency of dust collector.
Start-Up
Check that front access door is secured with knob, and that the dust drawer is closed with latch.
Check that the sequence switch is on.
nOTE:
Do not turn the sequence switch «on» until the cartridges are properly seasoned, page 13
Start the exhauster at the control panel, usually mounted on the blast cabinet. Check the pulse manifold pressure.
Shutdown
Run the collector until all media is recovered from the cabinet, and the cabinet is free of airborne dust.
Turn off the exhauster.
Turn off the compressed air supply valve.
Drain the pulse manifold whenever the compressed air supply is turned off. The drain petcock is mounted on the
side of the collector.
Empty contents from the dust drawer into a suitable container, per Section maintenance for dust drum page__
Manifold Pressure Module
The pressure regulator located on the pulse manifold inlet, adjust pulse pressure. Set initial pressure at 70 psi.
Pulse Sequence Control Panel
Your dust collector is equipped with an automatic cartridges cleaning system. You can see the condition of the
cartridges with the digital reader.
Pulse Sequence Control set up parameters
This module is controlled; it means you can change the parameters for maximum cartridges efficiency. Refer to DCT
1000
With key button (select) and (up) (down), you can change some parameters.
Your equipment is already factory set, before changing any parameters, take note of the initial parameters.
Parameters:
Process :
....................Value shown wile blower is running (inch of water, cartridges restriction)
Last Output :
........... Number of active solenoid (this value can not be change, system will detect
automatically the number of solenoid connected to the control card)
Time Off: ................
laps of time between each pulsation (value 10 seconds)
Time ON:
...................Valve pulsating time (250 msec value)
High Limit:
...............Value to which cleaning will start (value between 2.5 and 3.5)
Low limit:
.................Value to which cleaning will stop automatically (value between 2.5 and 3.5)
High Alarm:
.............Value to be reached to activate alarm (value High limit +2)
Low Alarm: .............
Value having to be reached to activate alarm (value =0)
Cycle Delay:
.............This value is for manual mode (value= 0)
Down time cycles:
.This value is for manual mode (value= 0)
Auto Alarm reset:
..This value is for manual mode (value= 0)
InITIAL STARTUP
ADJUSTMEnTS