T
he
reference
in
surface
TreaTmenT
International
Surface
Technologies
i s t s u r f a c e . c o m
9
AW16000 - Instruction Manual
Always wear a properly fitted and maintained, CSA, OSHA or nIOSH approved respirator and eye
protection when emptying the dust drawer. Failure to do so could result in respiratory disease or
serious respiratory and eye irritation. Toxicity and health risk vary with type of media, and dust
generated by blasting. Identify all material that is being removed by blasting, and obtain a Materials
Safety Data Sheet for the blast media.
Weekly
With the exhauster turned off, check the in-line dust filter dust accumulation. Check the exhaust air during a pulse
cycle. If dust is emitting from the exhauster, cartridges are leaking or damaged. Check immediately
With the exhauster turned off, empty the dust barrel. Heavily contaminated parts or friable media may require the
drawer be emptied more often. Never allow the drawer to become more than a quarter full.
WARnInG
all maintenance must be done with the electrical power locked-out and tagged-out, and
the compressed air supply line bled, locked-out and tagged-out. Failure to do so could result in death
or serious injury from electrical shock, unintentional actuation of a component, or from the venting of
trapped compressed air.
WARnInG : Failure to wear properly fitted and maintained, CSA, OSHA or nIOSH
approved respirator and eye protection when servicing dust laden areas of the dust
collector could result in serious eye irritation and lung disease or death. Toxicity and
health risk vary with type of media, and dust generated by blasting. Identify all material
that is being removed by blasting, and obtain a Materials Safety Data Sheet for the blast
media.
Empty the dust drum.
Open the front access door.
Remove the cartridges from the front access door . a small amount of force may be necessary to loosen the seal
of the cartridge gasket.
When cartridges are removed, clean the inside of the collector to remove loose or hardened dust, particularly
from the cartridge sealing surface, and the clean side (top side) of the cartridge sheet.
Install new cartridges; center each cartridge, install back the cartridge spacer and turn the locking to assure a
proper seal.
Inspect the access door gasket, replace if worn or damaged. Close the access door and secure.
PREVEnTIVE MAInTEnAnCE
SERVICE MAInTEnAnCE
REPLACInG FILTER CARTRIDGES