
______________________________
IST PROLINE
< Altitude Rank 0,1,2,3> < Altitude level Err over 6000 meters (19680 feet)>
Caution!
-
Even when there is no PGT(=pressure of gas in tissure) graph, a change in the altitude
rank will cause PGT graph to be displayed and desaturation time to be performed.
-
Never touch the water detection switch or expose it to moisture when on an airplane or in
any other environment where air pressure can change quickly.
-
When the PGT graph is high, a change in the altitude rank may cause nine level indicators
to appear for PGT. To prevent this, never use the dive computer when going to high-altitude
locations, since it will disable dive mode as a safety precaution. Normal function of the dive
computer will be restored when PGT graph drops to 8 or less level.
-
Difference of one-minute may occur between when the PGT graph is turned off and when
desaturation time is turned off.
-
A battery indicator Icon is used to indicate battery life. Be sure to replace the battery when
this battery Icon appears (ON or blinking).
Button functions
<Normal>
•
A: EL back light is on from 4-5 seconds.
•
B: Press this switch to move to dive set mode.
•
C: EL back light is on from 4-5 seconds.
•
D: When water is detected, the mode moves to dive mode.
<Surface condition (after a dive)>
•
A: EL back light is on from 4-5 seconds.
•
B: Press this switch to move to dive set mode , but if surface time is less than 10 minutes,
the mode moves to dive plan mode, not dive set mode. (In gage mode, move to gage dive set
mode display, but if surface time is less than 10 minutes, the mode moves to dive log mode .)
•
C: EL back light is on from 4-5 seconds.
•
D: When water is detected, the mode moves to dive mode.
Blink
______________________________
IST PROLINE
2.2.2. Dive set mode (Gage dive set mode)
If surface time is less than 10 minutes after dive, it cannot enter this mode.
The gray squares indicate blinking data
Description of Functions
•
Fraction of oxygen (=FO
2
): This displays the current setting.
MIX1 setting range: Fraction of oxygen 21-50%
、
’
--
’%.
MIX2 setting range: Fraction of oxygen 21-99%
、
’
--
’%.
•
Maximum depth of PO
2
: Based on the fraction of oxygen, this indicates the water depth
where PO
2
(=pressure of oxygen) maximum reaches 1.4 (MIX1) or 1.6(MIX2).
In the water depth rank which exceeded the maximum water depth, non-decompression
limit become displayed ‘---’.
•
User Safety Factor (=USF): When the level is "0" the usual algorithm is used for calculations.
When the level is “1” and “2”the next higher altitude rank is used for calculations. The
default setting is “0”.
•
Profiling time: It is the setting of sampling time. The setting range: either 15 or 30 seconds.
•
Battery indicator Icon: This displays the current battery voltage.
Max.
depth
of PO2
User Safety Factor
Oxygen percentage
Sea/Fresh Icon
Gage Icon
Profiling time
NITROX Icon
Dive time alarm
Max.
depth
alarm