background image

  

 

MEASUREMENT AND ASSEMBLY MANUAL 

 

Instruction validity: as of 1 August 2013 

7. WIRING OF LITE SCREEN ROLLER BLIND 

Observe instructions indicated in the installation instructions for the motor supplied with this manual. 

 

All wiring must be made in accordance with valid IEC standards. Use impulse switches together with the control 

unit in all situations where there is more than one device to control the same roller blind. The control unit will store 

the provided impulse for approx. 3 minutes or until receiving another command. 

NOTE:  In  order to  have  the installation correspond  to  international  standards, a  safety  cut-off  device  having  the 

contact opening distance of at least 3 mm must be installed in front of the circuit. 

 

In  case  of  installation  of  several  roller  blinds  with  group  controls,  where  the  user  cannot  see  all  the  windows,  adopt  all 

measures to prevent that any persons or objects impede the movement of the roller blinds. 

 

Do not connect two or more motors to the same control unit without using a group control unit. Do not use light 

switches. Do not connect two or more switches to the same motor. 

 

Do not use switches with blocking without a control unit for group control, otherwise there is a risk of a duplicate 

command with consequent motor short-circuiting. 

 

Any  damage caused  by  failure  to comply  with  the above instructions shall not  be attributed  to  the  manufacturer 

and 

shall lead to a loss of guarantee

 

8. ROLLER BLIND ADJUSTMENT AND TESTING 

8.1 ADJUSTING MOTOR SWITCH LIMITS 

NOTE: 

Wiring,  installation  and  maintenance must  be carried  solely  by  qualified personnel,  authorised and  competent  for 

said  operations.  The  roller  blind  can  be  supplied  either  with  a  standard  motor,  or  with  a  RTS  motor  with  an  integrated 

remote control receiver: 

 

STANDARD MOTOR: 

The motor cable has 4 conductors: 

 

blue = neutral conductor, 

 

brown = opening/closing, 

 

black = opening/closing, 

 

yellow-green = ground. 

 

When  connecting  the  conductors  to  a  terminal  block  inside  the  main  switch,  check  which  brown  and  black  conductor 

corresponds to opening and which to closing of the roller blind (this depends on which side of the drum the motor is to be 

installed). 

 

RTS MOTOR:

 

The motor cable has 3 conductors: 

 

blue = phase/neutral conductor, 

Summary of Contents for SCREEN LITE

Page 1: ...ed in the order form b attachment in front of an opening As a rule indicate the width of the opening which is to be shaded in the order form Dimensions outside the stipulated limits must be consulted with the manufacturer H height Measure the overall height including the roller blind upper section and holder DIMENSIONS OUTSIDE THE STIPULATED LIMITS MUST ALSO BE CONSULTED WITH THE MANUFACTURER COLO...

Page 2: ...depends of the model In case of outdoor installation if adverse weather conditions arise it is strongly recommended to draw the roller blind up to the box For motorised roller blinds it is recommended to use a wind sensor for the automatic roller drawing to the box 2 1 REQUIREMENTS FOR OPERATION All activities described for the installation maintenance and control of the motor end switches should ...

Page 3: ... Any intervention however small in the power supply requires a qualified electrician Faulty wiring faulty installation and any repairs adjustments or alterations made by any unauthorised personnel shall result in the loss of guarantee We recommend using solely original accessories and spare parts Our roller blinds are intended only for the use of original accessories DURING INSTALLATION Installati...

Page 4: ...lind function regularly Do not use the roller blind if maintenance is necessary 5 UNPACKING The SCREEN GW system is supplied partially assembled only the guide bars or cord accessories and ceiling brackets are packed separately After removing the packaging material check the roller blind for completeness and eventual visible damage to the components upper box guide bars etc If unsure do not use th...

Page 5: ...esponsible for defects caused by faulty installation 6 2 ROLLER BLIND INSTALLATION TO CEILING OR WALL Start the screen roller blind installation to the ceiling by marking out the attachment holes of the supporting brackets The distance of the screws from the roller blind edge should be 30 mm The screw spacing is 76 mm Leave a gap of at least 5 mm between the wall or ceiling and the supporting brac...

Page 6: ...table for the type of structure onto which they are to be attached metallic structure cement brick etc For front guide bar installation self adhesive covers are supplied to cover the attachment screw holes Once the installation is finished check parallelism and rectangularity of the guide bars This can be done by measuring two distances S1 and S2 or diagonals D1 and D2 The dimensions must be the s...

Page 7: ... D1 and D2 The dimensions must be the same 1 mm 6 5 EXTERIOR INSTALLATION WITH SLEEVE PASSING THROUGH WALL For exterior roller blinds installed with a sleeve passing through a wall and with a crank rod in the interior it is necessary to calculate the exact position of the hole for a 30 cm angular rod 15 Attach the brackets to a wall or ceiling and install the roller blind in its place Use a pencil...

Page 8: ...using a group control unit Do not use light switches Do not connect two or more switches to the same motor Do not use switches with blocking without a control unit for group control otherwise there is a risk of a duplicate command with consequent motor short circuiting Any damage caused by failure to comply with the above instructions shall not be attributed to the manufacturer and shall lead to a...

Page 9: ...nd and give this manual to the user for future reference NOTE There is a risk of compression in case a hand is trapped between the fabric and the upper box during the roller blind updrawing Before operating the roller blind move your hands outside of the movement range to prevent compression Vibrations or excessive noise indicate damage or faulty installation of the roller blind 8 2 TESTING To pro...

Page 10: ...your hands outside of the movement range to prevent compression Forced operation can cause damage to the roller blind 9 1 SAFETY DEVICES The motor includes a disconnecting overheating protection Thermal disconnection is activated after approx 4 6 minutes of continuous operation Before reactivating let the roller blind motor cool out Should you need assistance contact your dealer and ask for origin...

Page 11: ... not scrub by force OUTDOOR ROLLER BLIND SCREEN LITE DEFECT POSSIBLE CAUSE SOLUTION Fabric does not roll properly fabric side displacement Uneven fabric thickness manufacturing defect of the fabric Apply a distance layer e g adhesive tape directly onto the winding drum on the side opposite to where the fabric is moving Repeat applying further adhesive tape layers until the defect is completely rem...

Page 12: ... Increased noise Motor failure Disconnect the motor test it and replace if necessary Motor blocks after a long period of service The motor is in the thermal disconnection phase Wait for several minutes until the motor cools down NOTE Put the switch into neutral position to prevent its restart or uncontrolled operation Absolute absence of movement Improper wiring Check power supply at the switch Ch...