background image

14F 

 6. Troubleshooting  

 

Following are a few common problems that may occur during operation. Here are 

some suggestions for easy troubleshooting: 

 

A. The unit does not work, no light and the fan does not work 

1.  Check the connect power and main fuse. 

2.  Measure the mains voltage on the main connector. 

3.  Check the power on LED. 

B. Not responding to DMX controller

 

1.  Check the address settings and DMX polarity. 

2.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the unit or the previous one. 

3.  Try to use another DMX controller. 

4.  Check in the DMX cables run near or run alongside to high voltage cables that may     

cause damage or interference to DMX interface circuit.   

C. One of the channels is not working well 

1.  The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.  The motor’s drive IC on the PCB might be out of condition. 

D. The lamp is cutting out intermittently 

1. The lamp is not working well. Check the main voltage either too high or too low. 

2. Internal temperature may be too high. Check and if necessary replace the fan.

 

 

 

 

 

 

 

 

 

 

 

15F 

  7. Fixture Cleaning   

 

The cleaning of internal and external optical lenses and/or mirrors must be carried out 

periodically to optimize light output. Cleaning frequency depends on the environment in 

which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater 

accumulation of dirt on the unit’s optics. 

 

Clean with soft cloth using normal glass cleaning fluid. 

 

Always dry the parts carefully. 

 

Clean the external optics at least every 20 days. Clean the internal optics at least every 

30/60 days.

 

 

 

EC

  Declaration of Conformity 

We declare that our products (lighting equipments) comply with the following 

specification and bears CE mark in accordance with the provision of the 

Electromagnetic Compatibility (EMC) Directive 89/336/EEC. 

 

EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002; 

EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996, 

EN61000-4-11: 1994. 

Harmonized Standard 

 

EN 60598-1: 2004 

IEC 60598-1:2003+ corrigendum 2004 

Part 1:General requirements and test 

 

Following the provisions of the low voltage directive 73/23/EEC and 93/68/EEC 

 

 

 

 

 

 

Summary of Contents for FOLL02

Page 1: ...chnical Specification 2 1 Inserting Exchanging Rotating Gobos 2 2 Beam Angle 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjust 5 How To Control The Unit 5 1 Uni...

Page 2: ...be very hot In the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunctio...

Page 3: ...ischarge lamp would explode during operation The lamp emits intense UV radiation which is harmful to the eyes and skin The high luminance of the arc can cause severe damage to the retina if looks dire...

Page 4: ...g of the other side of the socket and snap the other end of the lamp into place Make sure it fits correctly into the socket Please refer to the diagram to know how to put the lamp in correct position...

Page 5: ...display will show the number of working hours of the unit To go back to the functions press the MENU button again 9F Reset Press the MENU button until the is blinking on the display Pressing ENTER bu...

Page 6: ...hange press the MENU button again Please refer to the following diagram to address your DMX512 channel for the first 4 units 6 Channels 11F 5 2 Dedicated Controller IF series has 6 channels for intern...

Page 7: ...istor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug from the output of the unit to the i...

Page 8: ...either too high or too low 2 Internal temperature may be too high Check and if necessary replace the fan 15F 7 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors mus...

Page 9: ...575W version Fuse 6 x 30 mm Glass T15A HMI 1200W version 6 x 30 mm Glass T10A HMI 575W version Lamp MSI 1200W S HMI 1200 S K SFc10 4 HMI 575W Dimension 1170 x 330 x 225 mm 405 x 360 x 35 mm Controlle...

Reviews: