background image

10F 

  Dimmer offset     

Press the 

MENU

 button for at least 5 seconds into offset mode, use 

DOWN

 and 

UP

 button 

up to when the 

  is shown on the display. Pressing 

ENTER

 button and the display will 

blink. Use 

DOWN

 and 

UP

 button to adjust the dimmer home position. Once the effect has 

been  selected,  press  the 

ENTER

  button  to  setup  or  automatically  return  to  the  offset 

functions  without  any  change  press  the 

MENU

  button  again,  To  go  back  to  the  main 

functions without any change after 8 seconds. 

  5. How To Control The Unit 

Two ways to operate: 

1. By universal DMX controller 

  2. By dedicated controller 

No  need  to  turn  the  unit  off  when  you  change  the  DMX  address,  as  new  DMX  address 
setting will be effected at once. Every time you turn the unit on, it will show 1200 on the 
display and move all the motors to their ‘home’ position and you may hear some noises for 
about 20 seconds. After that the unit will be ready to receive DMX signal. 

  5.1 DMX Controller   

If you use a universal DMX controller to control the units, you have to set DMX address from 
1 to 512 channels so that the units can receive DMX signal. 
Press the 

MENU

 button up to when the 

is shown on the display. Pressing 

ENTER

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. 

Once the address has been selected, press and keep 

ENTER

 button pressed up to when 

the  display  stops  blinking  or  storing  automatically  8  seconds  later.  To  go  back  to  the 
functions without any change press the

 MENU

 button again.   

Please refer to the following diagram to address your DMX512 channel for the first 4 units. 
6 Channels

11F 

  5.2 Dedicated Controller   

IF-series has 6 channels for international protocol DMX512. It can finish all operations via 
dedicated  controller  without  using  other  controllers.  When  the  power  is  switched  on,  the 
projector automatically starts to run the self-test. After finishing these, the fixture is ready for 
operation.

1.

DIMMER OPEN buttons

: Holding the buttons, the light beam will become more stronger 

and stronger, then shutter will obtain max. value. After un-holding it, the light beam and 
shutter resumes its initial condition. There are 2 buttons on the both sides of the controller 
for your convenient operation. 

2.

IRIS  OPEN  buttons

:  Holding  the  buttons,  the  light  iris  will  become  more  bigger  and 

bigger. After un-holding it, the light beam resumes its initial condition. There are 2 buttons 
on the both sides of the controller for your convenient operation. 

3.

FIXED COLOURS & RAINBOW switch

: Turning the switch on the RAINBOW position, 

enable the rainbow function, you can set different rainbow speed by pressing 

COLOUR 

buttons

 from slow to fast. Turning the switch on the 

FIXED COLOURS

 position, enable 

the  fixed  colors  function  and  disable  the  rainbow  function.  They  will  save  last  setting 
automatically in each step. 

4.

COLOUR  buttons

:  There  are  9  color  buttons  of  white,  red,  yellow,  magenta,  green, 

orange, blue, pink and purple. Select the light beam colors by pressing the relative color 
buttons.

5.

COLOUR  TEMPERATURE  switch

:  Adjusting  this  switch  to  obtain  3  kinds  of  color 

temperature: Standard 6000K, 5600K and 3200K. 

Summary of Contents for FOLL02

Page 1: ...chnical Specification 2 1 Inserting Exchanging Rotating Gobos 2 2 Beam Angle 3 Lamp 4 How To Set The Unit 4 1 Control Panel 4 2 Main Function 4 3 Home Position Adjust 5 How To Control The Unit 5 1 Uni...

Page 2: ...be very hot In the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunctio...

Page 3: ...ischarge lamp would explode during operation The lamp emits intense UV radiation which is harmful to the eyes and skin The high luminance of the arc can cause severe damage to the retina if looks dire...

Page 4: ...g of the other side of the socket and snap the other end of the lamp into place Make sure it fits correctly into the socket Please refer to the diagram to know how to put the lamp in correct position...

Page 5: ...display will show the number of working hours of the unit To go back to the functions press the MENU button again 9F Reset Press the MENU button until the is blinking on the display Pressing ENTER bu...

Page 6: ...hange press the MENU button again Please refer to the following diagram to address your DMX512 channel for the first 4 units 6 Channels 11F 5 2 Dedicated Controller IF series has 6 channels for intern...

Page 7: ...istor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug from the output of the unit to the i...

Page 8: ...either too high or too low 2 Internal temperature may be too high Check and if necessary replace the fan 15F 7 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors mus...

Page 9: ...575W version Fuse 6 x 30 mm Glass T15A HMI 1200W version 6 x 30 mm Glass T10A HMI 575W version Lamp MSI 1200W S HMI 1200 S K SFc10 4 HMI 575W Dimension 1170 x 330 x 225 mm 405 x 360 x 35 mm Controlle...