![Isokern STANDARD 36 Owner'S Manual Download Page 5](http://html1.mh-extra.com/html/isokern/standard-36/standard-36_owners-manual_2093415005.webp)
1.
Before starting the STANDARD fireplace and DM 54
chimney installation, read these installation instructions
carefully to be sure you understand them completely. Failure to
follow them could cause fireplace malfunction resulting in serious
injury or property damage.
2.
Always check local building codes governing fireplaces and
fireplace installations. The STANDARD fireplace and DM chim
-
ney installation must comply with all local, regional, state and
national codes and regulations.
3.
STANDARD fireplace and DM 54 chimney systems are
intended for use in any application where a traditional masonry
type fireplace would apply. The chimney system must always
vent vertically to the outside of the building.
4.
Creosote and soot formation and the need for removal: When
wood is burned slowly, it produces tar and other organic vapors
which combine with expelled moisture to form creosote. The
creosote vapors condense in the relatively cool chimney flue of
a slow burning fire. As a result, creosote residue accumulates on
the flue lining. When ignited this creosote makes an extremely
hot fire.
Because of creosote and soot buildup it is necessary to
inspect and clean the fireplace and chimney prior to use and peri
-
odically during the heating season. Cleaning of the fireplace and
the chimney system should be done annually at a minimum. In
colder climates, chimney cleaning may need to be done periodi-
cally throughout the heating season.
5.
Before servicing, allow the fireplace to cool. Always shut off
any electricity or gas to the fireplace while working on it.
6.
Use only solid fuel or natural or LP gas log sets in this unit. Do
not use artificial wax based logs, chemical chimney cleaners or
flame colorants in this fireplace.
7.
Never use gasoline, kerosene, gasoline-type lantern fuel,
charcoal lighter fluid, or similar liquids to start or “freshen up” a
fire in this fireplace. Keep all flammable liquids at a safe distance
from the fireplace.
8.
Always keep the flue damper open when heat is present in the
fireplace.
9.
Do not use a fireplace insert or any other product not speci
-
fied for use with the STANDARD fireplace and DM 54 chimney
systems unless written authorization is given by Isokern. Failure
to heed this warning may cause a fire hazard and will void the
Isokern warranty.
10.
This fireplace is not intended to heat an entire home or to be
used as a primary heat source. It is designed to ensure homeown
-
er comfort by providing supplemental heat to the room.
11.
Always ensure that an adequate supply of replacement com
-
bustion air from the outside of the house is accessible to the fire
to support normal combustion. Fireplaces consume large volumes
of air during the normal firing process.
In the event the home is tightly sealed and has modern
energy efficient features, the optional combustion air supply kits
may not provide all the air required to support combustion and
the proper flow of combustion gases up the chimney.
The manufacturer is not responsible for any smok-
ing or related problems that may result from the lack of
adequate air supply flowing into the house. It is the respon
-
sibility of the builder/contractor to ensure that adequate air
supply has been provided for the fireplace.
12.
“Smoke free” operation is not warranted nor is the
manufacturer responsible for inadequate system draft caused
by mechanical systems, general construction conditions,
inadequate chimney heights, adverse wind conditions or
any unusual environmental conditions or factors beyond the
manufacturer’s control.
Caution:
When used with the STANDARD fireplace
system, all gas log sets must be operated with the damper
clamped in the fully open position. This includes unlisted
“vent free” log sets. Only listed “vent free” log sets may be
operated with the damper in the closed position.
13.
When in doubt about a component’s usability - has vis-
ible or suspected physical damage - consult your Isokern
distributor or authorized Isokern representative for advice.
14.
Modification to STANDARD components not men
-
tioned in this manual may void claims, listings and approv-
als and could result in an unsafe and potentially dangerous
installation.
Alterations to the STANDARD firebox are allowed
with prior written approval and instructions from Earthcore
Industries, LLC. The installer indemnifies the manufacturer
of all claims and under no circumstances will manufacturer
be liable for consequential, incidental, indirect, punitive or
other damages of any kind or nature, whether foreseeable or
not, based on any claim by any party as to the modifications
of the Isokern fireplaces.
15.
Wherever insulation is used, the STANDARD fireplace
must not be placed directly against it. Keep all insulation or
vapor barriers a minimum of three inches (3”) away from all
fireplace and chimney components.
It is recommended that insulation and vapor barriers, if
used, first be covered with gypsum board, plywood, particle
board or other material to assure that insulation and vapor
barriers remain in place.
WARNING:
Do not pack required air spaces with
insulation or other materials.
16.
Never leave children unattended when there is a fire
burning in the fireplace.
17.
Burning some fuels (such as charcoal) can be hazard
-
ous due to the possibility of producing carbon monoxide,
a colorless, odorless gas. Early signs of carbon monoxide
poisoning resemble flu symptoms, including headaches,
dizziness or nausea. Over exposure to carbon monoxide
can lead to illness and death. It is strongly recommended to
install smoke and carbon monoxide alarm / detector devices
wherever fireplaces are in use.
5
Safety Instructions