15
COMMISSIONING
The UVC Hunter model is supplied assembled but with the lamps separately; after the installation of the lamps
(see paragraph “maintenance and changing lamps”) the product is ready to be connected to the electricity supply
network, referring to what is reported in the paragraph “Connection to the electricity network”.
WARNING! VERIFY THAT THE NUMBER PLATE DATA ARE COMPATIBLE WITH THAT OF THE
POWER SUPPLY LINE, PENALTY DAMAGE TO THE PRODUCT.
After connecting the plug, to the socket of the electrical system, operate the switch under the pedestal; the timer will be off
and the reset button with green ring will be on (security lockout situation).
From this condition it is necessary to press the reset button positioned to the right of the timer and then the start button on
the timer to start the sanitation cycle.
The time of the sanitation cycle will start but the UVC lamps and presence sensors are disabled for 30 seconds, the time
required for the operator to leave the room to be sa-
nitized.
If the exit did not take place within 10 sec, the sy-
stem will go back to lockout as someone will be de-
tected.
To the left of the timer there is a small red LED that
flashes during the time available for exit
It is suggested to place the UVC Hunter trolley at a distance of no more
than 4 meters from each perimeter wall (preferably in the center of the
environment you want to sanitize) and to leave it at least one meter away
from the closest object (so as to do not create gray areas).