background image

14

DESCRIPTION OF UVC HUNTER COMPONENTS

CAUTION!!

THE UNPACKING, ASSEMBLY, INSTALLATION AND COMMISSIONING OPERATIONS OF THE VARIOUS 

COMPONENTS MUST ONLY BE CARRIED OUT BY TECHNICAL PERSONNEL.

PACKAGING REMOVAL

The equipment is supplied with suitable outer carton packaging and shockproof inner material.

During unpacking operations be careful not to damage the surfaces and the particular places

inside the packaging as they are sensitive to bumps and scratches.

Keep the packaging for the duration of the warranty. The packaging materials must then be disposed of in

accordance with the regulations in force in the country of destination of the product.

Before installing, check the integrity of the device; in case of transport damage, contact the dealer.

Attenzione!

Il prodotto utilizza radiazioni UVC potenzialmente pericolose; non utilizzare il prodotto in presenza di persone 
o altri esseri viventi; 

SONO POSSIBILI DANNI AGLI OCCHI E ALLA PELLE 

THE PRODUCT IS INTENDED FOR INDOOR USE ONLY AND IS NOT SUITABLE FOR WET EN-

VIRONMENTS.

TO AVOID THE RISK OF FIRE OR ELECTRIC SHOCK, THE APPLIANCE MUST NOT BE USED 

WHERE

CONTACT WITH WATER IS POSSIBLE.

THE APPLIANCE MUST NOT BE USED IN POTENTIALLY EXPLOSIVE ATMOSPHERES.

 INSTALLATION 

UVC HUNTER

Once the packaging has been removed, the equipment is presented in the following way excluding the lamps that are sup-
plied separate in order to guarantee their integrity during transport.

6 x 55 W UVC lamps

Upper structure that includes the 2 
handles for moving the trolley

Timer 

Pulsante reset

Basic structure containing the electrical con-
trol parts

5 x IR sensors, 1 on each side of 
the base and 1 on the top of the 
central column

Swivel wheels, 2 of which with brake

Summary of Contents for UVC HUNTER

Page 1: ...P S r l Italian Spa Beauty and Tanning Equipment contact isoitalia com www isobenessere com www isoitalia com USER S MANUAL Read all precautions and instructions in this manual before using this equipment www steril line com UVC HUNTER ...

Page 2: ...ATION COMMISSIONING OF THE APPLIANCE AS WELL AS OPERATIONS OF EXTRAORDINARY MAINTENANCE AND PERIODIC PRO GRAM CHECKS MUST ONLY BE CARRIED OUT BY TECHNICAL PERSONNEL SUITABLY TRAINED USING ONLY ORIGINAL SPARE PARTS AFTER REMOVING THE PACKAGING ENSURE THE INTEGRITY OF THE PRODUCT If in doubt do not use it and contact the point of sale for a suitable analysis of the problems encountered The manufactu...

Page 3: ...or system out side the provisions of this manual Do not replace the components with non original MATERIALS or in any case not sup plied by the ISO Italia GROUP as they may compromise the correct operation of the appliance DO NOT DAMAGE PUNCTURE CUT OR OPEN ANY COMPONENT THAT IS PART OF THE EQUIPMENT AVOID ANY CONTACT BETWEEN THE EQUIPMENT AND POSSIBLE OPEN FLAMES INCANDESCENT OR BLUNT OBJECTS THAT...

Page 4: ...nce of 1 mt Electronic timer K400 2M K400 2M 200 240Vac MPI17618 Internal hour meter that cannot be reset MPI17603 Operating temperature 10 C 55 C ELECTRICAL CHARACTERISTICS Model Single phase supply voltage Vac Electricity frequency Hz Electric power max W HUNTER UVC 230 50 350W ELECTROMAGNETIC FIELDS Model Maximum measured weighted value Maximum limit imposed CEI EN 62233 outcome Hunter UVC 0 07...

Page 5: ... Width 400 mm Height 1500 mm Depth 400 mm Indicative weight 25 Kg The handling of the Hunter trolley must be carried out with caution through the handles on the upper structure as the lamps are visible and therefore fragile if they are accidentally hit TIMER Reset button Handles Average noise Protection against liquids IP20 Noise level IP rating ...

Page 6: ...ndards used as a reference for compliance with the essential requirements are as follows For safety CEI EN 60335 1 Safety of household and similar electrical appliances Part I For magnetic fields CEI EN 62233 measurement methods for electromagnetic fi elds of household and similar electrical appliances with reference to human exposure The product covered by this declaration has been marked in acco...

Page 7: ...pecial light signal positioned on the central column warns of the sanitization process in pro gress In the case of entry of people during the sanitization process the security system connected with the presence detectors turns off the equipment At the end of the sanitation cycle UVC Hunter switches off automatically We suggest positioning UVC Hunter at a distance of no more than 4 meters from each...

Page 8: ... below in the different configurations 99 of bacteria are killed on the surfaces and objects that are irradiated COMMANDS For operation the appliance is equipped with Timer positioned in the upper part of the central column for setting the time and starting the sanitation cycle detailed programming instructions are given in the paragraph relating to the timer A reset button to the right of the tim...

Page 9: ...nexpensive and eco friendly as no chemicals are added to air water and there are no hazardous or toxic chemicals to dispose of Benefits of UVC germicidal systems Disinfection times are rapid with a typical disinfection cycle lasting about 15 minutes excluding germicidal air systems This allows extremely fast turnover times for sanitising environments For its simplicity UV C disin fection is extrem...

Page 10: ... ozone layer micro organisms have not developed a natural defence against UV C energy When the DNA of a micro organism absorbs UV C energy molecular instability occurs resulting in interruption of the DNA sequence This makes the cell unable to grow or reproduce Without the ability to reproduce the cell cannot infect and dies quickly The application of UV C energy to inactivate micro organisms is k...

Page 11: ...icial by the end of October However all bacteria and viruses tested to date many hundreds over the years including coronaviruses are eliminated by UV disinfection UVC rays or germicidal range inactive i e kill eliminate at least two other coronaviruses that are the closest relatives of the COVID 19 virus SARS CoV and MERS CoV Large scale preparation of UV inactivated SARS coronavirus virions for v...

Page 12: ...12 ...

Page 13: ...tart the countdown press the START key the display will begin to show the passage of time in the decrease mode By pressing the STOP key the countdown can be stopped at any time and the timer will return to the previously set time When the time reaches zero the timer will beep for about 10 seconds To reset the set time keep the SET key pressed for a few seconds FEATURES Microprocessor based on a ti...

Page 14: ...ttenzione Il prodotto utilizza radiazioni UVC potenzialmente pericolose non utilizzare il prodotto in presenza di persone o altri esseri viventi SONO POSSIBILI DANNI AGLI OCCHI E ALLA PELLE THE PRODUCT IS INTENDED FOR INDOOR USE ONLY AND IS NOT SUITABLE FOR WET EN VIRONMENTS TO AVOID THE RISK OF FIRE OR ELECTRIC SHOCK THE APPLIANCE MUST NOT BE USED WHERE CONTACT WITH WATER IS POSSIBLE THE APPLIANC...

Page 15: ...situation From this condition it is necessary to press the reset button positioned to the right of the timer and then the start button on the timer to start the sanitation cycle The time of the sanitation cycle will start but the UVC lamps and presence sensors are disabled for 30 seconds the time required for the operator to leave the room to be sa nitized If the exit did not take place within 10 ...

Page 16: ... THE ELECTRICITY NETWORK WARNING the connection to the electricity grid must be made only by technical personnel with the neces sary skills on systems certified and equipped with a declaration of conformity on systems protected with 6A differential magnetothermic switch Before activating the switch located below the base of the appliance make sure that the data of the power line correspond to thos...

Page 17: ...ly the new lamps are inserted by doing the opposite In order to maintain the sanitizing and germicidal efficiency of UVC HUNTER it is essential to scrupulously comply with the maintenance program indicated below CAUTION Before any type of maintenance especially internal ones it is mandatory to disconnect the components from the power supply For some of the maintenance operations it is necessary to...

Page 18: ...ssistance it is recommended to use the form below keeping it together with the product manual Model equipment maintenance program Serial number Date intervention description replaced materials Note N 01 02 03 04 05 06 07 08 09 10 11 12 13 ...

Page 19: ...19 ...

Page 20: ...iving from industrial processes or agricultural artisan commercial or service activities which in view of their quantity of characteristics are not classified as normal household refuse DEMOLITION AND DISCHARGE OF THE UNIT The unit must be considered as AEE electrical and electronic unit and must be discharge as it is The under reproduced symbol indicates that the unit at the end of its life has t...

Page 21: ...ISTICS AND USE 6 DECLARATION OF CONFORMITY 6 FUNCTIONAL CHARACTERISTICS AND USE 7 BASIC CONCEPTS UV RAYS 9 TIMER K400 13 INSTALLATION AND COMMISSIONING 14 CONNECTION TO THE ELECTRICITY NETWORK 16 MAINTENANCE 17 WIRING DIAGRAMS 19 CORRECT DISPOSAL OF THE PRODUCT 20 GENERAL INDEX UVC HUNTER ...

Reviews: