SAFETY WARNINGS
This product is only intended for indoor air sanitation purposes, and for surface
sanitization (non-medical devices).
The product is not suitable for sanitizing / sterilizing / disinfecting medical devices.
•
This product must not be equipped with a general lighting lamp, also the UVC
lamp used in this product shouldn’t be installed in general lighting devices.
•
This product is intended for professional use only. The installation must be carried out by spe-
cialized technical personnel able to verify its correct functioning and subsequent maintenance.
•
By purchasing this product you declare that you are purchasing it for professional use only and
you undertake to instruct and inform the staff for correct use.
• It is strictly forbidden to use this product in environments where flammable and explosive
materials are present.
This product emits UVC light During operation, always avoid direct or reflected exposure of UVC
light with people or animals.
The UVC radiation produced during operation can cause severe damage to the eyes or
skin even after relatively short exposure times.People or animals are not
allowed to remain in the environment where the UVC lamps are in use.
Start the sanitation process only if the environment has been cleared of
people and animals.
Here are some indications to follow in order to operate in complete safety; one or more options
listed below can support the achievement of this goal.
•
Lock or block access to the environment while the UVC lamps are operating
•
Pay attention to the warning lights on the control console of the product be-
fore accessing the environment in which sanitation is in progress.
•
The product must only be operated by trained personnel informed on regular
use.
•
The control console must be positioned outside the environment to be sanitized, if this is not
possible, it is necessary to exit the environment to be sanitized within the delay time provided
for the lighting of the lamps after the start command.
•
The product includes a device to detect any presences in conjunction with the operation of
the UVC lamps; this safety device blocks the control system in case it is activated. The system
remains blocked until a forced reset which must be done by trained personnel.
•
In case of inactivity of the system for extended periods it is recommended to switch off the
device from the switch positioned on the side of the control console, or the switch of the sy-