The components of the Steril Room systems (UVC corner and control console) are each supplied with mechanical acces-
sories (screws and plugs) for their assembly but without the electrical connections between one component and the other;
these connections must be prepared in advance by the customer at the place of installation of the products; for the various
connections and the connection to the electricity grid it is necessary to refer to what is stated in the paragraph, Connection
to the electricity grid.
WARNING! VERIFY THAT THE PLATE DATA ARE COMPATIBLE WITH THAT OF THE POWER SUP-
PLY LINE PENALTY THE PRODUCT DAMAGE
The UVC corner module can be installed in the following ways:
•
directly fixed to the wall both horizontally and vertically, at an angle or on a flat surface according
to needs
•
suspended on the ceiling by means of two steel cables adjustable in height
The UVC corner module is mainly composed of three parts
1. the external protection grid in polished steel
2. internal support for electrical components, reflector and UVC lamp
3. oven-painted metal structure with the use of epoxy powders which includes the predispositions for inputs and outputs
of electrical connections and points for mechanical fixing
ASSEMBLY AND COMMISSIONING
1
Protection grid in
stainless steel with po-
lished finish and pre-
sence sensor
To remove the grid from the appliance, simply remove the 4 blind nuts at the points indicated then sliding it off the pins of
the structure below. When removing it, it is important to pay attention to the presence sensor hooked to the grill by means
of a metal bracket and connected via a connector inside the metal body. The sensor must not be removed from the grill.
2
Internal support
UVC lamp ballast
lamp holder
lamp holder
Reflective parabola
UVC lamp
To remove the internal support, the UVC lamp must first be removed (see indications on the lamp replacement paragraph)
and then unscrew the two screws that secure it to the structure, in the two points indicated by the red circle.
When removing the internal support it is necessary to pay attention to the electrical connections; the internal support is
linked to the metal structure by means of two cables in order to facilitate any maintenance.
For the connections, refer to the next paragraph on connection to the mains.
IR sensor