Steril Room 20100E     

ISO ITALIA GROUP S.r.l.

Italian Spa Beauty and Tanning Equipment

[email protected]

www.isobenessere.com

www.isoitalia.com

USER’S  MANUAL

Read all precautions and instructions in this manual

before using this equipment 

www.steril-line.com

Steril Room 

Summary of Contents for Steril Room

Page 1: ...P S r l Italian Spa Beauty and Tanning Equipment contact isoitalia com www isobenessere com www isoitalia com USER S MANUAL Read all precautions and instructions in this manual before using this equipment www steril line com Steril Room ...

Page 2: ...ATION COMMISSIONING OF THE APPLIANCE AS WELL AS OPERATIONS OF EXTRAORDINARY MAINTENANCE AND PERIODIC PRO GRAM CHECKS MUST ONLY BE CARRIED OUT BY TECHNICAL PERSONNEL SUITABLY TRAINED USING ONLY ORIGINAL SPARE PARTS AFTER REMOVING THE PACKAGING ENSURE THE INTEGRITY OF THE PRODUCT If in doubt do not use it and contact the point of sale for a suitable analysis of the problems encountered The manufactu...

Page 3: ...or system out side the provisions of this manual Do not replace the components with non original MATERIALS or in any case not sup plied by the ISO Italia GROUP as they may compromise the correct operation of the appliance DO NOT DAMAGE PUNCTURE CUT OR OPEN ANY COMPONENT THAT IS PART OF THE EQUIPMENT AVOID ANY CONTACT BETWEEN THE EQUIPMENT AND POSSIBLE OPEN FLAMES INCANDESCENT OR BLUNT OBJECTS THAT...

Page 4: ...mp 1 7 W m at a distance of 1 mt Electronic timer K400 2M K400 2M 200 240Vac MPI17618 Internal counter cannot be reset MPI17603 Operating temperature 10 C 55 C ELECTRICAL CHARACTERISTICS Template TSingle phase supply voltage V AC Mains frequency Hz Electric power max for each module W Corner UVC 230 50 55 ELECTROMAGNETIC FIELDS Template Maximum measured weighted value Maximum limit imposed IEC EN ...

Page 5: ...ns is provided in the center in the upper part Overall dimensions Control console size Width 265 mm Height 175 mm Depth 80 mm Indicative weight 2 Kg circa Wall mounted electrical panel inside the control console Passage for IN and OUT connections on the con trol console Fissaggio su ambo i lati per il coperchio consolle Fastening on both sides for the console cover When removing the cover it is ne...

Page 6: ...h 1150 mm Width 210 mm Thickness 90 mm Weight 8 kg approx Average noise Protection against liquids IP20 Noise Grado IP The red circles with larger dimensions indicate the predispositions for the pas sage of the electrical connections The two smaller black circles indicate the points for mechanical fixing to the wall or for mounting quick couplings for suspended installations ...

Page 7: ...ot allowed to remain in the environment where the UVC lamps are in use Start the sanitation process only if the environment has been cleared of people and animals Here are some indications to follow in order to operate in complete safety one or more options listed below can support the achievement of this goal Lock or block access to the environment while the UVC lamps are operating Pay attention ...

Page 8: ... given in the appropriate paragraph in order to avoid damage to the light source and other compo nents il n delle plafoniere da utilizzare è legato alla dose UVC che si vuole ottenere in funzione alle dimensioni dell ambiente da sanificare Una dose insufficiente di UVC potrebbe non raggiun gere l effetto di sanificazione previsto La dose inoltre può variare in funzione del tempo di servizio impieg...

Page 9: ...E 2011 65 EU RoHS The harmonised standards used as a reference for compliance with the essential requirements are as follows For safety CEI EN 60335 1 Safety of household and similar electrical appliances Part I For magnetic fields CEI EN 62233 measurement methods for electromagnetic fields of household and similar electrical appliances with reference to human exposure The product covered by this ...

Page 10: ...r nell ambiente è collegato ad un comando a tempo posizionato fuori dall ambiente stesso L operatore può attivare il Sistema UVC costituito da tutti i moduli posizionati all interno della stanza solo dall esterno azionando il timer presente sulla consolle comandi Al termine del ciclo di sanificazione gli UVC Corner si spegneranno automaticamente Quando gli UVC Cor ner sono in funzione un apposito ...

Page 11: ...d in official tables for the destruction of microorganisms we can indicate that with the cycles shown below in the different configurations it is possible to eliminate 99 of the bacteria on the surfaces and objects that are irradiated COMMANDS A control console is provided for system operation to be installed outside the environment to be sanitized For dimensional indications refer to the technica...

Page 12: ...nexpensive and eco friendly as no chemicals are added to air water and there are no hazardous or toxic chemicals to dispose of Benefits of UVC germicidal systems Disinfection times are rapid with a typical disinfection cycle lasting about 15 minutes excluding germicidal air systems This allows extremely fast turnover times for sanitising environments For its simplicity UV C disin fection is extrem...

Page 13: ... ozone layer micro organisms have not developed a natural defence against UV C energy When the DNA of a micro organism absorbs UV C energy molecular instability occurs resulting in interruption of the DNA sequence This makes the cell unable to grow or reproduce Without the ability to reproduce the cell cannot infect and dies quickly The application of UV C energy to inactivate micro organisms is k...

Page 14: ...icial by the end of October However all bacteria and viruses tested to date many hundreds over the years including coronaviruses are eliminated by UV disinfection UVC rays or germicidal range inactive i e kill eliminate at least two other coronaviruses that are the closest relatives of the COVID 19 virus SARS CoV and MERS CoV Large scale preparation of UV inactivated SARS coronavirus virions for v...

Page 15: ...15 ...

Page 16: ...ovescia premere il tasto START il display inizierà a visualizzare lo scorrere del tempo nella modalità a decremento Premendo il tasto STOP si può fermare il conto alla rovescia in qualsiasi momento e il timer tornerà sul tempo precedentemente impostato Quando il tempo arriverà a zero timer emetterà un segnale acustico per circa 10 secondi Per azzerare il tempo impostato tenere premuto il tasto SET...

Page 17: ...VI RONMENTS TO AVOID THE RISK OF FIRE OR ELECTRIC SHOCK THE APPLIANCE MUST NOT BE USED WHERE CONTACT WITH WATER IS POSSIBLE THE APPLIANCE MUST NOT BE USED IN POTENTIALLY EXPLOSIVE ATMOSPHERES UVC Corner module with po lished steel protection grid and passive IR sensor for detecting the presence of people INSTALLAZIONE Steril Room Control console consisting of a metal support where the electrical c...

Page 18: ...nted metal structure with the use of epoxy powders which includes the predispositions for inputs and outputs of electrical connections and points for mechanical fixing ASSEMBLY AND COMMISSIONING 1 Protection grid in stainless steel with po lished finish and pre sence sensor To remove the grid from the appliance simply remove the 4 blind nuts at the points indicated then sliding it off the pins of ...

Page 19: ... end and screw the conical end to the previously fixed plate so that the 2 steel cables descend from the ceiling and will anchor themselves to the corresponding quick clamps on the metal structure Metal support struc ture III Insert the steel cable that descends from the ceiling on each of the 2 quick hooks The quick couplings have the upper final part that acts as a cable clamp that must be screw...

Page 20: ...ral ceiling lights 4x 0 5mm 12 Vdc line power supply IR sensor for presence detection from terminal n 5 positive 12Vdc brown color to terminal n 1 C2F connector 2 brown color from terminal n 6 negative 12Vdc black color to terminal n 2 C2F connector 2 black color from terminal n 7 NC contact line 12Vdc gray color to terminal n 3 C2F connector 2 yellow green color from terminal n 8 NC contact line ...

Page 21: ...uipment itself the lamps have been mounted correctly all components and accessories are correctly located in their place WARNING IT IS STRICTLY FORBIDDEN TO TAMPER THE PRESENCE DETECTION SENSORS AS IT COMPROMISES THE SAFETY OF PEOPLE AND ANIMALS Passage for IN and OUT con nections on control console Electric wall panel for control console hour counter 230Vac 12Vdc power supply Lamp relay Safety lo...

Page 22: ...ng and germicidal efficiency of the Stril Room components it is essential to scrupulously comply with the maintenance program indicated below CAUTION Before any type of maintenance especially internal ones it is mandatory to disconnect the components from the power supply For some of the maintenance operations it is necessary to refer to the working hours of the lamps which are stored by means of ...

Page 23: ...ssistance it is recommended to use the form below keeping it together with the product manual Model equipment maintenance program Serial number Date intervention description replaced materials note N 01 02 03 04 05 06 07 08 09 10 11 12 13 ...

Page 24: ...24 ...

Page 25: ...25 ...

Page 26: ...iving from industrial processes or agricultural artisan commercial or service activities which in view of their quantity of characteristics are not classified as normal household refuse DEMOLITION AND DISCHARGE OF THE UNIT The unit must be considered as AEE electrical and electronic unit and must be discharge as it is The under reproduced symbol indicates that the unit at the end of its life has t...

Page 27: ...NGS 7 DECLARATION OF CONFORMITY STERIL ROOM 9 FUNCTIONAL CHARACTERISTICS AND USE 10 BASIC CONCEPTS UV RAYS 12 TIMER K400 16 INSTALLATION AND COMMISSIONING 17 CONNECTION TO THE ELECTRICITY NETWORK 21 MAINTENANCE 22 WIRING DIAGRAMS 24 CORRECT DISPOSAL OF THE PRODUCT 26 GENERAL INDEX Steril Room ...