ELECTRICAL CONNECTIONS
Warning :
All electrical connections must be performed and completed by a qualified electric
technician in order to minimize chance of personnel injury or damage caused by wrong connection.
The cable must be directly connected to the machine. No intermediates should be used. The
following pages contain the necessary diagram of electrical connections.
Ensure that the Electric Net is capable of loading up to V.Double-check the grounding for a
safe operation. ( look at electricity plan )
ROTATION OF MOTOR
After all the electrics have been completed, start the machine as below and check the
rotationary axis of the motor.
Bring Main Switch to Pos 1
Bring Key Switch to Pos 1
Push the foot pedal
Check the rotation direction axis of the motor
Reverse connect the electrics by qualified electric technician to achieve right rotation direction.
Note :
When you push the button of up the roll on the commander control
panel, if rolls are moving up ( moving reverse position ) this means that motor is
moving the reverse position. We advise to change the electric cable connecting
points.
INSTALLATION FIGURE
Connection of operation plug to machine;