3-11
WPL-3000 SERVICE MANUAL 0077B
Test Mode 3
ROM Switch List
Test Menu 6: ROM SWITCH
Function Name
ROM Address Default Value
WPL Configuration
00 = Straight through (In-Line).
003A
01
01 = “L” shape.
Shelf Life
00 = Today counted as one day.
003B
00
01 = Today not counted (add one day to shelf life).
Stabilization Lock Count
Number of weight samples that must match before weight
003C*
04
reading is accepted.
Note:
Decrease value for faster operation.
A/D Conversion Speed
01 = Slow: slower throughput, most reliable.
003D*
02
02 = Medium: standard.
03 = Fast: fastest throughput.
Width of Stabilization Window
Difference in number of internal counts from previous sample
that will be accepted as the same weight.
003E*
02
Example:
02 =
±
2 count difference from last sample.
Note:
Increase value for faster operation.
* These changes must be registered to the A/D Board NV RAM.
See WPL-3000 setup instructions (Appendix A.1).
* Typical “Speed Up” settings are: 003C = 03, 003D = 03, and 003E = 03.
Summary of Contents for WPL-3000
Page 8: ...Contents ...
Page 24: ...WPL 3000 SERVICE MANUAL 0077B 2 12 Setup 2 ...
Page 26: ...WPL 3000 SERVICE MANUAL 0077B 3 2 Test Mode 3 3 1 MENU DIRECTORY DIAGRAM ...
Page 29: ......
Page 33: ......
Page 34: ......
Page 38: ......
Page 39: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 54: ......
Page 55: ......
Page 60: ...WPL 3000 SERVICE MANUAL 0077B 4 18 Setting Mode 4 ...
Page 68: ...WPL 3000 SERVICE MANUAL 0077B 5 8 Controller Unit 5 ...
Page 83: ......
Page 84: ......
Page 87: ......
Page 89: ......
Page 114: ......
Page 116: ......
Page 119: ...Appendix A 1 Installation Notes A 2 A 2 Label Format Worksheets A 9 ...