Manual No. 0158A
27/68
IWB
−
IWX Series (Overseas Use) Service Manual
Address
Data Contents
Data Range
Remark (default)
102A
Selecting ON/OFF key function (bit 0)
Selecting preset automatic call-up function (bit 1)
Selecting 16/24 digits printing (bit 2)
Selecting date printing function (bit 3)
0
∼
1 (F1)
0
∼
1 (F2)
0
∼
1 (F3)
0
∼
1 (F4)
102B
Selecting preset No. printing function (bit 4)
Selecting singe/consecutive chit print (bit 5)
Selecting tare weight printing function (bit 6)
Selecting upper/lower limit values printing function
(bit 7)
0
∼
1 (F5)
0
∼
1 (F6)
0
∼
1 (F7)
0
∼
1 (F8)
103A
Portrait setup (bit 0
∼
3)
0
∼
F (F9)
103B
Output message specifications (bit 4
∼
7)
0
∼
F (F10)
104A
Data output method (bit 0
∼
3)
0
∼
F (F11)
104B
Data output conditions (bit 4
∼
7)
0
∼
F (F12)
105A
Relay output signal setup (bit 0
∼
3)
0
∼
F (F13)
105B
Relay input signal setup (bit 4
∼
7)
0
∼
F (F14)
106A
Loud buzzer output setup (bit 0
∼
3)
0
∼
F (F15)
106B
Internal buzzer selection function (bit 4
∼
7)
0
∼
F (F16)
107A
Auto power OFF setup (bit 0
∼
3)
0
∼
F (F17)
107B
Reserve
108
∼
109
102
∼
107 checksum
―
Set data in the
Registration Mode
(Operation Manual)
Reference
Refer to the IWB/IBX
Operation Manual
110
∼
115
Measuring condition setup data
Refer to measurement
conditions setup table
116A
Country code (refer to country No. list)
0
∼
F
(Default 10: Japan)
116B
Reserve
0
117A
Reserve
0
117B
Reserve
0
118
∼
120
A/D zero point data (adref)
24 bit
121
∼
123
A/D calibration data (adwidth)
24 bit
124
Weighing capacity setup (refer to weighing capacity
setup table)
00
∼
99
(Default 1: 60kg)
125A
Japan only
0
∼
F
125B
Span adjusted flag
5H or others
5H = OK
others = Error
126, 127
100
∼
113 Checksum
―