Chapter 3 TEST MODE
3-18
IP-EMZ Service Manual
The adjustment method of a LABEL SENSOR
1. The adjustment method of a gain.
Touch the [LABEL SENSOR LEVEL] button.
Display field will change to green.
Touch the (
UV
) adjustment buttons. Press this
button again to change the display to white and set
adjustment data.
2. T
he check method of a sensor level.
Press the [FEED] key 2 or 3 times. Then, label comes
out.
Press the [2][0][0][0] at numeric keys. And press the
[PRESET] key. Then, graph pops up.
FEED
Label
Label gap
Graph in case a STD value is 0
PRESET
2
0
0
0