Chapter 3 TEST MODE
IL-2000SA Service Manual
3-11
¡
Peel Sensor Level
1. Adjustment of Peel Sensor
(1) Confirm that there is no label on the peel stand, and put into the state of light acceptance
state.
(2) The data field changes to green when the [PEEL SENSOR LEVEL] button is touched.
(3) Touch [
S
][
T
] keys to make the numeric value around “100”.
(4) Touch the [FEED] key to issue one label.
At this time, confirm that the peel sensor is shielded by the label.
(5) Confirm that the numeric value of [PEEL SENSOR LEVEL] is “20” or less.
Note: If the value is more than “20”, adjust the optical axis by bending the steel plate of the
emitting sensor bracket.
¡
Printer Adjustment
Touch the [PAGE] key, and set each item to perform test
print. Press the [PRINT] key to check whether the
printing is normal.